Comparison of reproducibility of dual-arch impression with conventional impressions

نویسندگان

  • Hiroyuki Minami
  • Shiro Suzuki
  • Takuo Tanaka
چکیده

Purpose: This study compared the reproducibility of dual-arch impression technique with conventional impression techniques. Materials and Methods: Full-crown preparation was completed on posterior teeth of fresh porcine upper jaws. Dual-arch impression was made immediately after the preparation without gingival retraction cord or triple-tray (experimental group), followed by conventional 1-step and 2-step impressions (control groups). Sub-marginal impression lengths were measured at the center of mesial, distal, buccal and palatal surfaces and compared among three groups. The accuracy was compared by calculating the ratios of the widths among stone casts generated from each impression for mesial-distal and buccal-palatal measurements. Differences among the groups were analyzed by Wilcoxon signed-ranks test at 95% confidence level. Results: Regarding sub-marginal lengths, there were no significant differences among three groups (p>0.05) at buccal site. However, dual-arch impression was significantly smaller than control groups at mesial site (p<0.05), smaller than 1-step impression group at distal site (p<0.05), and smaller than 2-step impression group at palatal site (p<0.05). There were no significant differences among three groups (p>0.05) for mesial-distal widths, however, buccal-palatal widths of the dual-arch impression was significantly smaller than the control groups (p<0.05); 99.1 % of 1-step group and 99.20 % of 2-step group. Conclusion: Sub-marginal lengths of dual-arch impression without using retraction cord seemed to be clinically sufficient. However, the use of triple-tray is recommended when the dual-arch impression techniques are employed. (Int Chin J Dent 2006; 6: 9-16.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

PURPOSE The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions wi...

متن کامل

In vivo Study of the Accuracy of Dual-arch Impressions.

BACKGROUND This study evaluated in vivo the accuracy of metal (Smart®) and plastic (Triple Tray®) dual-arch trays used with vinyl polysiloxane (Flexitime®), in the putty/wash viscosity, as well as polyether (Impregum Soft®) in the regular viscosity. MATERIALS AND METHODS In one patient, an implant-level transfer was screwed on an implant in the mandibular right first molar, serving as a patte...

متن کامل

A preliminary survey of impression trays used in the fabrication of fixed indirect restorations.

PURPOSE A variety of impression trays are used in the fabrication of fixed indirect restorations. Impressions used in the construction of fixed indirect restorations were examined for tray type, manner of use, and overall impression quality. MATERIALS AND METHODS A commercial dental laboratory provided 1403 impressions used to fabricate fixed indirect restorations during a 3-month period. Imp...

متن کامل

Effect of variation of impression material combinations, dual arch tray types, and sequence of pour on the accuracy of working dies: “An in vitro study”

AIMS To evaluate the accuracy of dies made from dual arch impressions using different sectional dual arch trays, combinations of elastomeric impression materials, and the sequence of pour of dies. SUBJECTS AND METHODS The dual arch impression materials were grouped into three groups depending on the combination of impression materials used and each group is subdivided into four subgroups. A s...

متن کامل

Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays.

STATEMENT OF PROBLEM Success rates for making fixed prosthodontic impressions based on material and tray selection are not known. PURPOSE The purpose of this clinical study was to compare first impression success rates for 2 types of impression material and 2 impression tray systems. MATERIAL AND METHODS Dual-viscosity impressions were made with a vinyl polysiloxane (VPS) (Aquasil Ultra Mon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010