Pulmonary blood flow redistribution by increased gravitational force.

نویسندگان

  • M P Hlastala
  • M A Chornuk
  • D A Self
  • H J Kallas
  • J W Burns
  • S Bernard
  • N L Polissar
  • R W Glenny
چکیده

This study was undertaken to assess the influence of gravity on the distribution of pulmonary blood flow (PBF) using increased inertial force as a perturbation. PBF was studied in unanesthetized swine exposed to -Gx (dorsal-to-ventral direction, prone position), where G is the magnitude of the force of gravity at the surface of the Earth, on the Armstrong Laboratory Centrifuge at Brooks Air Force Base. PBF was measured using 15-micron fluorescent microspheres, a method with markedly enhanced spatial resolution. Each animal was exposed randomly to -1, -2, and -3 Gx. Pulmonary vascular pressures, cardiac output, heart rate, arterial blood gases, and PBF distribution were measured at each G level. Heterogeneity of PBF distribution as measured by the coefficient of variation of PBF distribution increased from 0.38 +/- 0.05 to 0.55 +/- 0.11 to 0.72 +/- 0.16 at -1, -2, and -3 Gx, respectively. At -1 Gx, PBF was greatest in the ventral and cranial and lowest in the dorsal and caudal regions of the lung. With increased -Gx, this gradient was augmented in both directions. Extrapolation of these values to 0 G predicts a slight dorsal (nondependent) region dominance of PBF and a coefficient of variation of 0.22 in microgravity. Analysis of variance revealed that a fixed component (vascular structure) accounted for 81% and nonstructure components (including gravity) accounted for the remaining 19% of the PBF variance across the entire experiment (all 3 gravitational levels). The results are inconsistent with the predictions of the zone model.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of inertial load and countermeasures on the distribution of pulmonary blood flow.

We assessed the influence of cranial-to-caudal inertial force (+G(z)) and the countermeasures of anti-G suit and positive pressure breathing during G (PBG), specifically during +G(z), on regional pulmonary blood flow distribution. Unanesthetized swine were exposed randomly to 0 G(z) (resting), +3 G(z), +6 G(z), and +9 G(z), with and without anti-G suit and PBG with the use of the Air Force Rese...

متن کامل

سازوکارهای فعالیت، زیست مکانیک و تنظیم موضعی سیاهرگها

Many of the venous functions are biomechanical in their nature and/or related closely to biomechanical (hemodynamic) forces: 1 Blood conduits, collectors with flow-rectifying valves 2. Maintenance of filling pressure for the right heart by controlling venous return in the face of widely varying cardiac output arterial pressure buffer 3. Capacity function, redistribution of blood volume 4. Postc...

متن کامل

Paradoxical redistribution of pulmonary blood flow in prone and supine humans exposed to hypergravity.

We hypothesized that exposure to hypergravity in the supine and prone postures causes a redistribution of pulmonary blood flow to dependent lung regions. Four normal subjects were exposed to hypergravity by use of a human centrifuge. Regional lung perfusion was estimated by single-photon-emission computed tomography (SPECT) after administration of (99m)Tc-labeled albumin macroaggregates during ...

متن کامل

Redistribution of pulmonary blood flow impacts thermodilution-based extravascular lung water measurements in a model of acute lung injury.

BACKGROUND Studies using transthoracic thermodilution have demonstrated increased extravascular lung water (EVLW) measurements attributed to progression of edema and flooding during sepsis and acute lung injury. The authors hypothesized that redistribution of pulmonary blood flow can cause increased apparent EVLW secondary to increased perfusion of thermally silent tissue, not increased lung ed...

متن کامل

Echocardiographic evaluation of pulmonary venous blood flow and cardiac function changes during one-lung ventilation.

OBJECTIVES The intra-pulmonary shunt induced by one-lung ventilation (OLV), is alleviated by increased pulmonary blood flow by gravitational redistribution and hypoxic pulmonary vasoconstriction. We investigated the changes of pulmonary venous blood flow (PVBF) and biventricular function during OLV with echocardiography. And the correlation between PVBF and intra-pulmonary shunt fraction (Qs/Qt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 84 4  شماره 

صفحات  -