Continuous glucose monitoring in children with type 1 diabetes.
نویسندگان
چکیده
OBJECTIVE To examine the feasibility of daily use of a continuous glucose monitor, the FreeStyle Navigator Continuous Glucose Monitoring System ("Navigator"), in children with type 1 diabetes (T1D). STUDY DESIGN After a masked Navigator was used for 4 to 7 days to establish a baseline level of glycemic control, 30 insulin pump users with T1D (average age 11.2 years) were asked to use the Navigator daily for 13 weeks. RESULTS Subjects averaged 149 h/wk of Navigator use during the first 4 weeks, which decreased slightly to 134 h/wk during weeks 9 to 13 (P = .006). Mean hemoglobin A1c improved from 7.1% at baseline to 6.8% at 13 weeks (P = .02), and the percentage of glucose values between 71 and 180 mg/dL increased from 52% to 60% (P = .01). Subjects and parents reported high satisfaction with the Navigator on the Continuous Glucose Monitor Satisfaction Scale. Two subjects had severe skin reactions related to sensor mount adhesive. CONCLUSION This study indicates that incorporating real-time continuous glucose monitoring into the daily treatment of children with T1D is feasible. The results provide a compelling rationale for conducting a randomized trial of daily use of a continuous glucose monitor in children with T1D.
منابع مشابه
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
OBJECTIVE To assess the impact of continuous glucose monitoring on hypoglycemia in people with type 1 diabetes. RESEARCH DESIGN AND METHODS In this randomized, controlled, multicenter study, 120 children and adults on intensive therapy for type 1 diabetes and a screening level of glycated hemoglobin A(1c) (HbA(1c)) <7.5% were randomly assigned to a control group performing conventional home m...
متن کاملLimitations of conventional methods of self-monitoring of blood glucose: lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes.
OBJECTIVE Children with type 1 diabetes are usually asked to perform self-monitoring of blood glucose (SMBG) before meals and at bedtime, and it is assumed that if results are in target range, along with HbA(1c) measurements, then overall glycemic control is adequate. However, the brief glimpses in the 24-h glucose profile provided by SMBG may miss marked glycemic excursions. The MiniMed Contin...
متن کاملMitigating Severe Hypoglycemia by Initiating Inpatient Continuous Glucose Monitoring for Type 1 Diabetes Mellitus.
Continuous glucose monitoring for type 1 diabetes mellitus will go forward for refinement as a systematic review. The scope of this topic, including populations, interventions, comparators, and outcomes, will be further developed in the refinement phase. When key questions have been drafted, they will be posted on the AHRQ Web site and open for public comment. To sign up for notification wh...
متن کاملUse of continuous glucose monitoring in young children with type 1 diabetes: implications for behavioral research.
OBJECTIVE This study presents data on the use of continuous glucose monitoring (CGM) in young children with type 1 diabetes mellitus (T1DM). CGM provides moment-to-moment tracking of glucose concentrations and measures of intra- and interday variability, which are particularly salient measures in young children with T1DM. METHODS Thirty-one children (mean age = 5.0 yr ) with T1DM wore the Med...
متن کاملContinuous glucose monitoring and the reality of metabolic control in preschool children with type 1 diabetes.
OBJECTIVE To determine using the MiniMed continuous glucose monitoring system (CGMS) 1) whether twice-daily insulin injection therapy achieves adequate control in preschool children with type 1 diabetes and 2) whether the CGMS is more informative than self-monitoring of blood glucose (SMBG) regarding glucose control and well tolerated by preschool children and their families. RESEARCH DESIGN ...
متن کامل[Accuracy, utility and complications of continuous glucose monitoring system (CGMS) in pediatric patients with type 1 diabetes].
OBJECTIVE To evaluate the accuracy, utility and complications of continuous glucose monitoring system in children and adolescents with type 1 diabetes. METHODS This retrospective study assessed 16 type 1 diabetic patients (16.12+/-4.41 years) submitted to continuous glucose monitoring system (Medtronic; Northridge, CA) for 72 hours. The following parameters were analyzed: mean capillary gluco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of pediatrics
دوره 151 4 شماره
صفحات -
تاریخ انتشار 2007