Low-field vs. high-field proton MRS of mouse brain in vivo.
نویسندگان
چکیده
In a recent paper on in vivo proton MRS of mouse brain at 9.4 T, Tkáč et al. (1) reported high-quality single-voxel spectra of small volumes, but failed to accomplish a fair comparison with a previous study by Schwarcz et al. (2) at 2.35 T. Instead, the reader was left with the impression that proton MRS of mouse brain at low field strengths is of low value and is generally hampered by problems that are either absent or avoidable at 9.4 T. Although comparisons of MRI or MRS at different field strengths are usually confounded by a variety of other factors involving differences in radiofrequency coils, acquisition techniques, and postprocessing procedures, physiologic or biochemical quantities (such as metabolite concentrations) should of course be independent measures. Tkáč et al. (1) obtained total creatine (tCr) concentrations in mouse brain in vivo that were “in excellent agreement with the published values” reported by Schwarcz et al. (2). On the other hand, Schwarcz et al. (2) obtained strong interstrain variabilities, whereas Tkáč et al. (1) found only small (though significant) metabolite differences in the strains investigated. Assuming that the low-field study was incorrect, Tkáč et al. (1) offered a list of problems that may explain this discrepancy. In particular, they noted that “the shimming resulted in threefold broader line widths (in ppm) at 2.35 T” and that line widths decreased rather than increased post mortem. They further questioned a high in vivo concentration of glucose (Glc), a nonzero post mortem concentration of Glc, and complained about missing information about taurine (Tau). They concluded that these flaws all “[point] to systematic errors in quantification” in the work of Schwarcz et al. (2). The discrepancies between the two studies can be described as follows: 1) Strain differences. Tkáč et al. (1) compared C57BL/6 mice with CBA and CBA/BL6 mice and found interstrain differences that were “limited to Gln, Glu, Ins, Lac, NAAG, and PE,” whereas Schwarcz et al. (2) observed “substantially larger differences in metabolite concentrations between other mouse strains”—more precisely between C57BL/6 mice and BALB/c (tNAA, tCr, Cho, Glc, and Lac), but not NMRI mice (except for Glc). In other words, each study compared C57BL/6 mice with different strains and reported variable interstrain dependencies. Thus, in contrast to what was suggested by Tkáč et al. (1), both studies were consistent with each other and did not report conflicting results. 2) Spectral resolution. When given in units of Hz rather than in ppm, the line width allows for a direct comparison with the coupling constants of multiplet resonances, which for protons are on the order of 3–7 Hz. In fact, despite a better relative resolution at 9.4 T that facilitates the separation of glutamate and glutamine methylene multiplets, a full width at half maximum (FWHM) of 11–14 Hz (1) is worse than the 6.9–9.3 Hz reported for 2.35 T (2), and is not sufficient to unambiguously distinguish between lactate (Lac) and lipids. 3) Post mortem line width. Tkáč et al. (1) incorrectly stated that Schwarcz et al. (2) observed a decrease of the line width in C57BL/6 mice post mortem. In fact, the FWHM remained unchanged in C57BL/6 and BALB/c mice, and significantly increased for NMRI mice (see Table 2 in Ref. 2). 4) Glucose assignment. Although Tkáč et al. (1) did not identify Glc resonances in their spectra while they left no resonances unassigned (see Fig. 1 of Ref. 1), they reported Glc concentrations of 3–4 mol/g for different brain regions in C57BL/6 mice. In contrast, low-field spectra concentrate most of the intensity of the Glc protons in a well-defined apparent singlet at 3.43 ppm, which may be readily exploited for accurate quantification by LCModel. Moreover, whereas Schwarcz et al. (2) confirmed the Glc assignment and quantification by its rapid decrease post mortem (see Fig. 3 and Table 2 in Ref. 2), Tkáč et al. (1) did not perform such consistency experiments. 5) Glucose concentrations. Using a correction for CSF partial volumes, Schwarcz et al. (2) reported Glc concentrations of 6.2 2.3 and 5.4 2.7 mM for anesthetized NMRI and BALB/c mice, respectively, and 9.8 3.9 mM for C57BL/6 mice. This latter value was characterized as abnormally high and was suggested to reflect a strainrelated shift of the cerebral energy metabolism toward enhanced anerobic glycolysis and/or alterations of glucose transport. This understanding is in line with the wellknown vulnerability of the C57BL/6 strain to cerebral ischemia (see references in Ref. 2). It is also consistent with the simultaneous observation of much higher Lac concentrations in C57BL/6 mice (2.8 0.8 mM) than in NMRI (1.9 1.4 mM) and BALB/c mice (1.1 1.0 mM), while the Glc/Lac ratio was found to be similar in all three strains (2). 6) Lactate. In contrast to the results obtained at 2.35 T (see previous section), Tkáč et al. (1) reported in vivo Lac concentrations of 4.5–6.5 mol/g in the striatum of different strains. Such levels must be considered exceptionally high under normal physiologic conditions. Apart from putative difficulties with anesthesia, lipid suppression, and spatial selectivity of the voxel, it may also be an *Correspondence to: T. Michaelis, Biomedizinische NMR Forschungs GmbH, 37070 Göttingen, Germany. E-mail: [email protected] Received 1 October 2004; revised 18 January 2005; accepted 20 January 2005. DOI 10.1002/mrm.20668 Published online 13 September 2005 in Wiley InterScience (www.interscience. wiley.com).
منابع مشابه
نقش متابولیتها در تشخیص توده های مغزی با استفاده از طیف سنجی تشدید مغناطیس هسته ای و مقایسه غلظت آنها در بیماران تومورال با افراد سالم
Background and Aim: Brain tumors have remained as a significant cause of morbidity and mortality and are often refractory to treatment. The grading of brain tumor has an important implication in clinical management. Currently, magnetic resonance spectroscopy (MRS) is an important dimension in evaluating metabolites and grading brain tumors. The aim of this study is to evaluate metabolites in br...
متن کاملHandling macromolecule signals in the quantification of the neurochemical profile.
In vivo localized proton magnetic resonance spectroscopy (1H MRS) became a powerful and unique technique to non-invasively investigate brain metabolism of rodents and humans. The main goal of 1H MRS is the reliable quantification of concentrations of metabolites (neurochemical profile) in a well-defined region of the brain. The availability of very high magnetic field strengths combined with th...
متن کاملHigh Field In vivo 13C Magnetic Resonance Spectroscopy of Brain by Random Radiofrequency Heteronuclear Decoupling and Data Undersampling
In vivo13C magnetic resonance spectroscopy (MRS) is a unique and effective tool for studying dynamic human brain metabolism and the cycling of neurotransmitters. One of the major technical challenges for in vivo13C-MRS is the high radio frequency (RF) power necessary for heteronuclear decoupling. In the common practice of in vivo13C-MRS, alkanyl carbons are detected in the spectra range of 10-6...
متن کاملAdvances in High-Field Magnetic Resonance Spectroscopy in Alzheimer’s Disease
Alzheimer's disease (AD) affects several important molecules in brain metabolism. The resulting neurochemical changes can be quantified non-invasively in localized brain regions using in vivo single-voxel proton magnetic resonance spectroscopy (SV 1H MRS). Although the often heralded diagnostic potential of MRS in AD largely remains unfulfilled, more recent use of high magnetic fields has led t...
متن کاملIn vivo localized two dimensional MR spectroscopy to compare the neurochemical profile in wild-type and transgenic mouse model of Alzheimer’s disease
Introduction Currently a definitive diagnosis of Alzheimer’s disease (AD) is only possible postmortem, by detecting the two hallmarks of the disease: amyloid plaques and neurofibrillary tangles in the brain tissue. There is thus a great need for in vivo biomarkers to diagnose AD with high specificity and sensitivity. Proton magnetic resonance spectroscopy (H MRS) provides a non-invasive way to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 54 4 شماره
صفحات -