Early risk of mortality after coronary artery revascularization in patients with left ventricular dysfunction and potential role of the wearable cardioverter defibrillator.
نویسندگان
چکیده
BACKGROUND Implantation of implantable cardioverter defibrillator for prevention of sudden cardiac death is deferred for 90 days after coronary revascularization, but mortality may be highest early after cardiac procedures in patients with ventricular dysfunction. We determined mortality risk in postrevascularization patients with left ventricular ejection fraction ≤35% and compared survival with those discharged with a wearable cardioverter defibrillator (WCD). METHODS AND RESULTS Hospital survivors after surgical (coronary artery bypass graft surgery) or percutaneous (percutaneous coronary intervention [PCI]) revascularization with left ventricular ejection fraction ≤35% were included from Cleveland Clinic and national WCD registries. Kaplan-Meier, Cox proportional hazards, propensity score-matched survival, and hazard function analyses were performed. Early mortality hazard was higher among 4149 patients discharged without a defibrillator compared with 809 with WCDs (90-day mortality post-coronary artery bypass graft surgery 7% versus 3%, P=0.03; post-PCI 10% versus 2%, P<0.0001). WCD use was associated with adjusted lower risks of long-term mortality in the total cohort (39%, P<0.0001) and both post-coronary artery bypass graft surgery (38%, P=0.048) and post-PCI (57%, P<0.0001) cohorts (mean follow-up, 3.2 years). In propensity-matched analyses, WCD use remained associated with lower mortality (58% post-coronary artery bypass graft surgery, P=0.002; 67% post-PCI, P<0.0001). Mortality differences were not attributable solely to therapies for ventricular arrhythmia. Only 1.3% of the WCD group had a documented appropriate therapy. CONCLUSIONS Patients with left ventricular ejection fraction ≤35% have higher early compared to late mortality after coronary revascularization, particularly after PCI. As early hazard seemed less marked in WCD users, prospective studies in this high-risk population are indicated to confirm whether WCD use as a bridge to left ventricular ejection fraction improvement or implantable cardioverter defibrillator implantation can improve outcomes after coronary revascularization.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملRisk stratification for implantable cardioverter defibrillator therapy: the role of the wearable cardioverter-defibrillator.
The benefit of implantable cardioverter-defibrillator (ICD) therapy depends upon appropriate evaluation of a persisting risk of sudden death and estimation of the patient's overall survival. Assessment of a stable and unchangeable arrhythmogenic substrate is often difficult. Structural abnormality and ventricular dysfunction, the two major risk parameters, may recover, and heart failure symptom...
متن کاملOn-Pump Beating Coronary Artery Bypass in High Risk Coronary Patients
Background: There are some conflicting results with Conventional Coronary Artery Bypass Grafts (CCABG) with arrested heart in coronary high-risk patients. Moreover, performing off-pump CABG in these cases may be associated with serious complications. The objective of this study is to evaluate the efficacy of the on-pump beating CABG (OPBCABG) in coronary high-risk patients in comparison with th...
متن کاملInfarct characterization and quantification by delayed enhancement cardiac magnetic resonance imaging is a powerful independent and incremental predictor of mortality in patients with advanced ischemic cardiomyopathy.
BACKGROUND Infarct heterogeneity has been shown to be independently associated with adverse outcomes in previous smaller studies. However, it is unknown whether infarct characterization is an independent predictor of all-cause mortality in patients with advanced ischemic cardiomyopathy, after adjusting for clinical risk factors, severity of ischemic mitral regurgitation, incomplete revasculariz...
متن کاملMechanisms of sudden cardiac death in myocardial infarction survivors: insights from the randomized trials of implantable cardioverter-defibrillators.
Sudden death is a catastrophic but unpredictable complication of coronary artery disease and is frequently the consequence of an acute ischemic event.1–3 The efficacy of the implantable cardioverter-defibrillator (ICD) in reducing sudden cardiac death incidence is irrefutable and strongly supported by evidence from randomized trials of both primary and secondary prevention (Figure 1).4–8 Noneth...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 6 1 شماره
صفحات -
تاریخ انتشار 2013