Postmastectomy CT-based electron beam radiotherapy: dosimetry, efficacy, and toxicity in 118 patients.

نویسندگان

  • Marnee M Spierer
  • Linda X Hong
  • Raquel T Wagman
  • Matthew S Katz
  • Rebecca L Spierer
  • Beryl McCormick
چکیده

PURPOSE To evaluate the technique, dosimetry, acute and late toxicity, local control (LC), and overall survival (OS) with the use of computed tomography (CT)-based postmastectomy electron beam therapy (PMEBT) in high-risk patients. METHODS AND MATERIALS From 1990 to 2000, 118 patients with pathologic stage I-IIIB breast cancer underwent PMEBT of the chest wall (CW) (n = 3), CW and supraclavicular fossa (SCV) (n = 63), CW, SCV, and internal mammary lymph nodes (IMN) (n = 51), and SCV+IMN (n = 1). Radiation therapy was delivered with an en face electron beam with a custom cutout. Treatment plans were all CT-based. The plans of 16 patients were retrospectively reviewed to analyze dosimetry data. A retrospective chart review was conducted to assess acute and late complications, LC, and OS. RESULTS At a median follow-up of 43 months, 5-year LC and OS were 91% and 61%, respectively. Sixty-one patients developed acute grade 3-4 skin toxicity, necessitating treatment breaks in 33 patients. Fifteen patients experienced a worsening of lymphedema, and 2 patients developed cardiac injury thought to be unrelated to radiotherapy. No patients developed symptomatic pneumonitis. Dosimetric analysis revealed heart and lung normal tissue complication probabilities of zero. Analysis of other clinically relevant dosimetric parameters revealed PMEBT to be comparable to previously reported techniques. CONCLUSION Postmastectomy electron beam therapy is an effective way to deliver radiation to the postmastectomy chest wall and adjacent nodal sites. It offers acceptable acute and late toxicities and a high degree of local control given the high-risk population to which it is offered.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

متن کامل

Commissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran

Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...

متن کامل

Dosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam

Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradia­tion in post‑lump...

متن کامل

Evaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy

Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...

متن کامل

Electron Beam Dosimetry in Heterogeneous Phantoms Using a MAGIC Normoxic Polymer Gel

Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 60 4  شماره 

صفحات  -

تاریخ انتشار 2004