Incremental Prognostic Use of Left Ventricular Global Longitudinal Strain in Asymptomatic/Minimally Symptomatic Patients With Severe Bioprosthetic Aortic Stenosis Undergoing Redo Aortic Valve Replacement.

نویسندگان

  • Peyman Naji
  • Shailee Shah
  • Lars G Svensson
  • A Marc Gillinov
  • Douglas R Johnston
  • L Leonardo Rodriguez
  • Richard A Grimm
  • Brian P Griffin
  • Milind Y Desai
چکیده

BACKGROUND With improved survival of patients undergoing primary bioprosthetic aortic valve replacement (AVR), reoperation to relieve severe prosthetic aortic stenosis (PAS) is increasing. Timing of redo surgery in asymptomatic/minimally symptomatic patients remains controversial. Left ventricular (LV) global longitudinal strain (GLS) is a marker of subclinical LV dysfunction. In asymptomatic/minimally symptomatic patients with severe PAS undergoing redo AVR, we sought to determine whether LV-GLS provides incremental prognostic use. METHODS AND RESULTS We studied 191 patients with severe bioprosthetic PAS (63±16 years, 58% men) who underwent redo AVR between 2000 and 2012 (excluding mechanical PAS, severe other valve disease transcatheter AVR, and LV ejection fraction <50%). Society of Thoracic Surgeons score was calculated. Standard echocardiography data were obtained. LV-GLS was measured on 2-, 3-, and 4-chamber views using velocity vector imaging. Severe PAS was defined as aortic valve area <0.8 cm2, mean aortic valve gradient ≥40 mm Hg, and dimensionless index <0.25. A composite outcome of death and congestive heart failure admission was recorded. At baseline, mean Society of Thoracic Surgeons score, LV ejection fraction, mean aortic valve gradients, and right ventricular systolic pressure were 7±6, 58±6%, 54±10 mm Hg and 40±14 mm Hg, whereas 50% had >2+ aortic regurgitation. Median LV-GLS was -14.2% (-11.4, -17.1%). At 4.2±3 years, 41 (22%) patients met the composite end point (2.5% deaths and 1% strokes at 30 days postoperatively). On multivariable Cox survival analysis, LV-GLS was independently associated with longer-term composite events (hazard ratio, 1.21; 95% confidence interval, 1.10-1.33), P<0.01. The C statistic for the clinical model (Society of Thoracic Surgeons score, degree of aortic regurgitation, and right ventricular systolic pressure) was 0.64 (95% confidence interval 0.54-0.79), P<0.001. Addition of LV-GLS to the clinical model increased the C statistic significantly to 0.71 (95% confidence interval 0.58-0.81), P<0.001. CONCLUSIONS In asymptomatic/minimally symptomatic patients with severe bioprosthetic PAS undergoing redo AVR, baseline LV-GLS provides incremental prognostic use over established predictors and could potentially aid in surgical timing and risk stratification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of transcatheter aortic valve implantation on left ventricular mass and global longitudinal strain: tissue Doppler and strain evaluation

INTRODUCTION Transcatheter aortic valve implantation is the option of choice for high surgical risk patients suffering from symptomatic aortic stenosis. We aimed to evaluate the influence of baseline global longitudinal strain on left ventricular mass regression after the procedure. METHODS We enrolled 23 patients with pure symptomatic severe aortic stenosis who underwent CoreValve prosthesis...

متن کامل

Current management of calcific aortic stenosis.

Calcific aortic stenosis is a progressive disease with no effective medical therapy that ultimately requires aortic valve replacement (AVR) for severe valve obstruction. Echocardiography is the primary diagnostic approach to define valve anatomy, measure aortic stenosis severity, and evaluate the left ventricular response to chronic pressure overload. In asymptomatic patients, markers of diseas...

متن کامل

Exercise Echocardiography in Asymptomatic Patients with Severe Aortic Stenosis and Preserved Left Ventricular Ejection Fraction

The management of asymptomatic patients with severe aortic stenosis (AS) remains controversial. Recent series reported that early aortic valve replacement might be associated with improved clinical outcomes. However, the risk-benefit ratio should be carefully evaluated and early surgery only be proposed to a subset of asymptomatic patients considered at higher risk. Exercise echocardiography ca...

متن کامل

Association of myocardial deformation with outcome in asymptomatic aortic stenosis with normal ejection fraction.

BACKGROUND Current guidelines recommend intervention for symptomatic aortic stenosis, but the management of asymptomatic aortic stenosis remains controversial. As left ventricular global longitudinal strain (GLS) has been shown to predict cardiovascular outcome, we sought to find whether its use could guide the assessment of risk in these patients. METHODS AND RESULTS We prospectively followe...

متن کامل

Assessment of left ventricle function in patients with symptomatic and asymptomatic aortic stenosis by 2-dimensional speckle-tracking imaging

BACKGROUND Global longitudinal peak strain (GLPS) quantifies left ventricle (LV) long-axis contractility. Early detection of LV systolic dysfunction is pivotal in diagnosis and treatment of patients with aortic stenosis (AS). This study was performed to assess LV longitudinal systolic function by GLPS derived from 2-dimensional speckle tracking imaging (2D-STI) in AS patients in comparison to s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 2017