Echo-Train Pulse Sequences: EPI, RARE & Beyond

نویسنده

  • Jürgen Hennig
چکیده

Nearly all of MR-imaging in use today is based on a k-space approach making use of the fact, that a linear spatial encoding field – i.e. a gradient – leads to a linear variation of the Larmor frequency of spins. Localization is then achieved by Fourier transformation of the acquired time domain signal into the frequency domain, which directly corresponds to the spatial domain. Consequently two-dimensional k-space data have to be acquired in order to form a two-dimensional image. The challenge for MR image formation thus is to find a way to cover the two-dimensional k-space with an intrinsically one-dimensional signal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neuro MR: principles.

The principles of contrast mechanisms and fast pulse sequences underlying neurological and neuroradiological application of MRI are introduced in this part of a two-part review. In particular, the relaxation time constants T(1), T(2), and T(2) (*) are introduced, along with pulse sequences harnessing their contrast, spin-echo, fast spin echo (FSE), inversion recovery (IR), gradient recalled ech...

متن کامل

Two-dimensional spatially-selective RF excitation pulses in echo-planar imaging.

Two-dimensional spatially-selective RF (2DRF) excitation pulses were developed for single-shot echo-planar imaging (EPI) with reduced field of view (FOV) in the phase-encoding direction. The decreased number of k-space lines significantly shortens the length of the EPI echo train. Thus, both gradient-echo and spin-echo 2DRF-EPI images of the human brain at 2.0 T exhibit markedly reduced suscept...

متن کامل

Multiple gradient- and spin-echo EPI acquisition technique with z-shimming to compensate for susceptibility-induced off- resonance effects

INTRODUCTION – Images obtained with gradient-echo echo planar imaging (GRE-EPI) suffer from magnetic field variations within the brain, such as in regions adjacent to air-tissue interfaces. In these regions, magnetic field inhomogeneities cause spins to dephase more rapidly, resulting in signal dropouts. Thus, conventional GRE-EPI pulse sequences used for dynamic susceptibility-contrast perfusi...

متن کامل

GRAPPA-accelerated short axis BLADE EPI for multi-shot diffusion weighted imaging

Introduction: Artifacts in diffusion weighted EPI (DW-EPI) can be significantly reduced by increasing the speed with which k-space is traversed along the phaseencoding (PE) direction. The traverse speed can be increased through parallel acquisition techniques (PAT) [1] and by shortening the time between two successive samples in the PE direction (echo spacing ES). ES can be decreased through th...

متن کامل

Fast T2-weighted MR imaging: impact of variation in pulse sequence parameters on image quality and artifacts.

The purpose of this study was to quantitatively evaluate in a phantom model the practical impact of alteration of key imaging parameters on image quality and artifacts for the most commonly used fast T(2)-weighted MR sequences. These include fast spin-echo (FSE), single shot fast spin-echo (SSFSE), and spin-echo echo-planar imaging (EPI) pulse sequences. We developed a composite phantom with di...

متن کامل