Ventilation-perfusion inhomogeneity increases gas uptake in anesthesia: computer modeling of gas exchange.

نویسندگان

  • P J Peyton
  • G J Robinson
  • B Thompson
چکیده

Ventilation-perfusion (VA/Q) inhomogeneity was modeled to measure its effect on overall gas exchange during maintenance-phase N(2)O anesthesia with an inspired O(2) concentration of 30%. A multialveolar compartment computer model was used based on physiological log normal distributions of VA/Q inhomogeneity. Increasing the log standard deviation of the distribution of perfusion from 0 to 1.75 paradoxically increased O(2) uptake (VO(2)) where a low mixed venous partial pressure of N(2)O [high N(2)O uptake (VN(2)O)] was specified. With rising mixed venous partial pressure of N(2)O, a threshold was observed where VO(2) began to fall, whereas VN(2)O began to rise with increasing VA/Q inhomogeneity. This phenomenon is a magnification of the concentrating effects that VO(2) and VN(2)O have on each other in low VA/Q compartments. During "steady-state" N(2)O anesthesia, VN(2)O is predicted to paradoxically increase in the presence of worsening VA/Q inhomogeneity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventilation-perfusion inhomogeneity increases gas uptake: theoretical modeling of gas exchange.

Ventilation-perfusion (VA/Q) inhomogeneity was modeled to measure its effect on gas exchange in the presence of inspired mixtures of two soluble gases using a two-compartment computer model. Theoretical studies involving a mixture of hypothetical gases with equal solubility in blood showed that the effect of increasing inhomogeneity of distributions of either ventilation or blood flow is to par...

متن کامل

Effect of ventilation-perfusion inhomogeneity and N(2)O on oxygenation: physiological modeling of gas exchange.

Ventilation-perfusion (VA/Q) inhomogeneity was modeled to measure its effect on arterial oxygenation during maintenance-phase anesthesia involving an inspired mixture of 30% O(2) and either N(2)O or N(2). A multialveolar compartment computer model was constructed based on a log normal distribution of VA/Q inhomogeneity. Increasing the log SD of the distribution of blood flow from 0 to 1.75 prod...

متن کامل

PDPS: a pulmonary data processing system for assessment of gas exchange properties by multiple gas wash-out.

A data acquisition and processing system for the analysis of inert gas wash-out tests is described. The described system is in clinical use on spontaneously breathing patients as well as on mechanically ventilated Intensive Care patients. It combines several analysis techniques with an aim to provide a deeper insight into the nature of existing ventilation inhomogeneity than the individual tech...

متن کامل

Teaching with Technology Teaching pulmonary gas exchange physiology using computer modeling

Kapitan KS. Teaching pulmonary gas exchange physiology using computer modeling. Adv Physiol Educ 32: 61–64, 2008; doi:10.1152/ advan.00099.2007.—Students often have difficulty understanding the relationship of O2 consumption, CO2 production, cardiac output, and distribution of ventilation-perfusion ratios in the lung to the final arterial blood gas composition. To overcome this difficulty, I ha...

متن کامل

Validation of measurements of ventilation-to-perfusion ratio inequality in the lung from expired gas.

The analysis of the gas in a single expirate has long been used to estimate the degree of ventilation-perfusion (Va/Q) inequality in the lung. To further validate this estimate, we examined three measures of Va/Q inhomogeneity calculated from a single full exhalation in nine anesthetized mongrel dogs under control conditions and after exposure to aerosolized methacholine. These measurements wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 91 1  شماره 

صفحات  -

تاریخ انتشار 2001