Aseptic arthritis after ACL reconstruction by Tape Locking Screw (TLS®): report of two cases.
نویسندگان
چکیده
In Tape Locking Screw (TLS(®)) ligamentoplasty, transplant bone fixation uses polyethylene terephthalate (PET). We report two cases of aseptic arthritis following anterior cruciate ligament (ACL) reconstruction using this material. Diagnosis was founded on negative sampling and complete cure following arthroscopic lavage and synovectomy without curative antibiotherapy. This complication was also described with other synthetic materials used in this indication (Dacron, PFTE, carbon), and with PET as transplant material but never as bone fixation material. The physiopathological hypothesis is in terms of PET particle release in the suprapatellar bursa; sinking the strips into the bone as fully as possible on implantation could avoid impingement. Longer TLS(®) ligamentoplasty series with adequate follow-up will be needed in order to estimate the true incidence of this complication.
منابع مشابه
ACL Reconstruction Using a Short Hamstring Graft and Tape Locking Screw: A Biomechanical Study
Introduction: Anterior cruciate ligament (ACL) reconstruction is one of the most widely performed orthopaedic procedures in developed counties. Reconstruction using autograft soft tissue such as hamstring tendon has been the preferred choice by many for its superior strength and less donor-site morbidity over the bone-tendon-bone graft. Fixation of soft tissue graft, however, has been less than...
متن کاملThe Effect of Gentamycin in the Irrigating Solution to Prevent Joint Infection after Anterior Cruciate Ligament (ACL) Reconstruction
Background: Arthroscopic reconstruction of ACL is an effective method to restore knee stability after ACL rupture.Postoperative septic arthritis (SA) is very uncommon while the incidence of serious complications range between0.14% and 1.8%. Some of the devastating consequences of septic arthritis can encompass hyaline cartilage damage,arthrofibrosis, and in rare cases amputation. The purpose of...
متن کاملBroken Bioabsorbable Tibial Interference Screw after Anterior Cruciate Ligament (ACL) Reconstruction using a Semitendinosus-gracilis Graft: A Case Report.
ABSTRACT When a patient presents with knee pain and locking after an anterior cruciate ligament (ACL) reconstruction, a new meniscal injury or an osteochondral loose body are usually considered for differential diagnosis. We present the case of a 22-year-old female with just these complaints 6 months after ACL reconstruction surgery. Magnetic resonance imaging (MRI) of the knee showed a broken ...
متن کاملFemoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature
Background: A rare and devastating complication following anterior cruciate ligament (ACL) revision reconstruction is femoral fracture. Case presentation: A 35-year old male soccer player with a history of ACL tear from the previous year ago, who underwent arthroscopic ACL reconstruction and functioned well until another similar injury caused ACL re-rupture. Revision of ACL reconstruction w...
متن کاملReamed interlocking intramedullary nailing for the treatment of tibial diaphyseal fractures and aseptic nonunions. Can we expect an optimum result?
The need for reaming and the number of locking screws to be used in intramedullary (IM) tibial nailing of acute fractures as well as routine bone grafting of tibial aseptic nonunions have not been clearly defined. We describe the results of reamed interlocked IM nails in 233 patients with 247 tibial fractures (190 closed, 27 open and 30 nonunions). Ninety-six percent of the fractures were unite...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Orthopaedics & traumatology, surgery & research : OTSR
دوره 98 3 شماره
صفحات -
تاریخ انتشار 2012