Single-breath transfer factor in young healthy adults: 21% or 17.5% inspired oxygen?

نویسندگان

  • H Normand
  • C Marie
  • A Mouadil
چکیده

For the measurement of the single-breath transfer factor of the lung for carbon monoxide (TL,CO,sb), the American Thoracic Society (ATS) recommends using a test gas with a 21% inspired fraction of oxygen (FI,O2) whereas the European Respiratory Society (ERS) expressly recommends 17-18% FI,O2. The ERS committee argues that with a higher concentration (e.g. 21%) the alveolar fraction of oxygen (and accordingly TL,CO,sb) "varies with the volume of the test gas which is inspired", that is, presumably, in proportion to the volume of the test gas that is diluted in the alveolar volume. The current study measured TL,CO,sb and the transfer coefficient (KCO,sb) in duplicate in 67 healthy adults (age 17-23 yrs) using, in random order, an inspired gas containing either 17.5% or 21% oxygen. A correction was applied for carboxyhaemoglobin, in line with ATS recommendations. As expected, TL,CO,sb was higher with 17.5% FI,O2 test gas compared with 21% FI,O2 test gas (11.98 +/- 2.68 versus 11.38 +/- 2.56 mmol x min(-1) x kPa(-1), respectively) as well as KCO,sb (1.98 +/- 0.24 versus 1.90 +/- 0.23 mmol x min(-1) x kPa(-1), respectively). The ratio of TL,CO,sb measurements was strictly independent of the residual volume/total lung capacity ratio measured with plethysmography. Hence, the rationale used by the European Respiratory Society, which utilises a 17-18% inspired fraction of oxygen test gas for single-breath transfer of the lung for carbon monoxide measurements, would appear to be unwarranted in young healthy adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability of the single-breath carbon monoxide transfer factor as a function of inspired oxygen pressure.

We measured single-breath CO transfer factor (TLCO) and alveolar oxygen partial pressure (PAO2) six times at each of three fractions of inspired oxygen (FIO2) (0.17, 0.21, 0.26) in twelve healthy subjects, to determine whether one FIO2 would have the advantage of producing less variable TLCO results than the others. Measured TLCO was adjusted for the increase in carboxyhaemoglobin during the te...

متن کامل

Standardisation of gas mixtures for estimating carbon monoxide transfer factor.

BACKGROUND The American Thoracic Society recommends that the inspired concentration used for the estimation of carbon monoxide transfer factor (TLCO) mixture should be 0.25-0.35% carbon monoxide, 10-14% helium, 17-21% oxygen, balance nitrogen. Inspired oxygen influences alveolar oxygen and hence carbon monoxide uptake, such that transfer factor increases by 0.35% per mm Hg decrease in alveolar ...

متن کامل

Correction of the single breath carbon monoxide transfer factor in exercise for variations in alveolar oxygen pressure.

BACKGROUND Carbon monoxide transfer factor (TLCO) varies inversely with the partial pressure of alveolar oxygen (PAO2). During exercise the PAO2 in the alveolar gas sample bag decreases so the TLCO increases more than would be expected from the effects of exercise alone. The effects of PAO2 on the estimation of TLCO during exercise have been investigated and studies have been performed to deter...

متن کامل

Pulmonary function in healthy young adult Indians in Madras.

Forced vital capacity, forced expiratory volume in one second, functional residual capacity, residual volume, total lung capacity, and single breath diffusing capacity measurements (effective alveolar volume, carbon monoxide transfer factor, and transfer coefficient) were measured in 247 young healthy adults (130 male, 117 female) aged 15-40 years living in Madras. Subjects were of Dravidian st...

متن کامل

Rapid induction of halothane anaesthesia in man.

The cardiopulmonary and anaesthetic responses of nine healthy volunteers, breathing concentrations of 1-4% halothane in oxygen, were studied. Supine fasting subjects breathing room air exhaled to residual volume and then inhaled a vital capacity breath of 1, 2, 3 or 4% halothane in oxygen. After a breath-hold of 30-90 s they exhaled and then breathed spontaneously the same anaesthetic mixture f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2004