EVLA Memo 177 Polarimetric calibration and dynamic range issues
نویسندگان
چکیده
This memo considers some dynamic range issues resulting from limitations in the polarimetric calibration solutions used in typical observations. Whereas we focus on “traditional” radio interferometric telescopes such as the VLA, ATCA or ALMA, the analysis approach can be used for other interferometer arrays. The memo is mostly concerned with the principles: rather than addressing real data, this memo focuses on analysis. The discussion generally applies to any feed system, including linearly or circularly polarized feeds and arrays of heterogeneous (i.e. dissimilar) feeds. Generally we consider the calibration information available from an observation of a point source calibrator at a single frequency at the field center at a single instant in time. However the added constraints provided by parallactic rotation are also considered. We will consider the effect when this calibration information is applied to the data of a target source. For brevity, we will assume that the Stokes total intensity of the calibrator source is 1 Jy, and that the target source is also 1 Jy.
منابع مشابه
EVLA Memo: #139 Plan for Imaging Algorithm Research and Development
Many scientific deliverables of the next generation radio telescopes require widefield imaging or high dynamic range imaging, or both. Some next generation telescopes nearing completion (EVLA and ALMA) indeed promise at least a ten-fold increase in the sensitivity compared to the existing telescopes. High imaging dynamic range requires removal of systematic errors to high accuracy and for long ...
متن کاملEVLA Memo 160 More WIDAR spectral dynamic range tests
This is a continuation of investigation of the spectral dynamic range achievable with the WIDAR correlator. Previous investigations (EVLA Memo 148) were limited by the so-called “splatter” phenomena, which is now understood and avoidable (EVLA Memo 157). This investigation is also stimulated by a desire to evaluate the “correlator chip beat artifact” seen in simulations (NRC-EVLA Memo 32) and t...
متن کاملImaging/calibration algorithm research
This note discusses the proposed plan for research on imaging and calibration algorithm development related to EVLA/ALMA. Attempt here is to describe briefly a work plan to address two problems which will need to be addressed in a few years from now, which also look tractable and towards which some work has already been done. In the sections below, the problems of continuum imaging with a bandw...
متن کاملEVLA Memo 148 WIDAR anti-aliasing and spectral dynamic range test
WIDAR, the correlator being commissioned as part of the EVLA upgrade, allows observing with multiple simultaneous subbands. Intrinsically WIDAR produces many channels within each subband. WIDAR aims to be a system with high spectral purity. In particular, WIDAR aims to produce low non-ideal in-band response of a spectral feature, low aliasing of a spectral feature from one subband to another, a...
متن کاملEVLA Memo #100 Correction of errors due to antenna power patterns during imaging
Errors in the observed visibilities can be classified as direction dependent and direction independent effects. Since direction dependent effects are different for each source, they must be corrected during imaging. This memo is concerned with the problem of correcting for such effects during imaging. We demonstrate that the effects of known receptor pointing errors (including polarization squi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014