Rotation effects on the target-volume margin determination.

نویسندگان

  • Qinghui Zhang
  • Weijun Xiong
  • Maria F Chan
  • Yulin Song
  • Chandra Burman
چکیده

Rotational setup errors are usually neglected in most clinical centers. An analytical formula is developed to determine the extra margin between clinical target volume (CTV) and planning target volume (PTV) to account for setup errors. The proposed formula corrects for both translational and rotational setup errors and then incorporated into margin determination for PTV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

متن کامل

The Effects of the Shape and Size of the Clinical Target Volume on the Planning Target Volume Margin

PURPOSE To investigate the impact of clinical target volume (CTV) shape and size on CTV to planning target volume (PTV) margin expansion. METHODS AND MATERIALS Using numerical integration methods, margins accounting for random errors and systematic errors were calculated for CTVs of different shapes and sizes. We use k(r-95) and k(s-95) to represent the coefficients, for random errors and sys...

متن کامل

Correlation between patients’ anatomical characteristics and interfractional internal prostate motion during intensity modulated radiation therapy for prostate cancer

Intensity modulated radiation therapy (IMRT) is one of a standard treatment for localized prostate cancer. Although lower complication is expected for smaller target margin, determination of optimal margin is important. For bony-structure based registration, internal prostate motion is the main factor determining the margin from clinical target volume to planning target volume. The purpose of t...

متن کامل

Determination the structure of oriental beech, Fagus orientalis Lipsky stands (Case study: Asalem watershed forests, north of Iran)

Modification of stands’ structure and managing them using silvicultural methods close to nature and single selection system require information on status of structure, determining the target diameter, basal area and suitable volume to result in long-term equilibrium and sustainability. So, this study was conducted using the selection sample statistical method by selecting  five 1-ha sample plot...

متن کامل

Dosimetric pitfalls in the application of shielding disk in breast intraoperative electron radiation therapy

Introduction: Intraoperative electron radiotherapy (IOERT) is an IORT technique in which electron beams with different nominal energies are used for irradiation of microscopic residual of tumor bed after surgery. Application of a shielding disk, which is positioned under the target volume, for protecting the normal tissues such as pectoral muscle, lung, and heart is one of the a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 2015