Aerosol kinetics and bronchodilator efficacy during continuous positive airway pressure delivered by face mask.

نویسندگان

  • S N Parkes
  • A D Bersten
چکیده

BACKGROUND Rates of fresh gas flow (FGF) commonly used when continuous positive airway pressure (CPAP) is delivered by face mask theoretically reduce the delivery and availability of therapeutic aerosols. As it may be hazardous for patients with acute respiratory failure to interrupt mask CPAP, the effects of CPAP on aerosol kinetics and bronchodilator efficacy were investigated. METHOD The effect of CPAP at 10 cm H2O at a FGF rate of 50 l/min on the delivery of technetium labelled aerosol generated from a readily available jet nebuliser was measured using a bench model of spontaneous respiration. In a separate clinical study the bronchodilator responses to incremental doses of nebulised salbutamol were measured in nine stable asthmatic subjects in a random sequence of conventional nebulisation (control) or nebulisation whilst receiving CPAP via a tight fitting face mask. Each patient acted as his or her own control. RESULTS CPAP significantly reduced total aerosol delivery to the face mask from 6.85 (1.52)% to 1.3 (0.37)% of the initial nebuliser charge. In the clinical study a significant bronchodilator response to nebulised salbutamol was seen during both conventional nebulisation and nebulisation whilst receiving CPAP by face mask. The shape of the dose-response curves and the magnitude of the total increase in the forced expiratory volume in one second (FEV1) was identical for CPAP and control conditions. CONCLUSIONS Despite a reduction in aerosol presented to the proximal airway, the bronchodilator response to inhaled beta 2 agonists in stable asthmatic subjects was not affected when CPAP was delivered by face mask. Despite a high rate of FGF, nebulised beta 2 agonists are effective when administered in conjunction with CPAP delivered by face mask.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aerosol delivery and humidification with the Boussignac continuous positive airway pressure device.

BACKGROUND A simple method for effective bronchodilator aerosol delivery while administering continuing continuous positive airway pressure (CPAP) would be useful in patients with severe bronchial obstruction. OBJECTIVE To assess the effectiveness of bronchodilator aerosol delivery during CPAP generated by the Boussignac CPAP system and its optimal humidification system. METHODS First we a...

متن کامل

Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.

BACKGROUND The key to successful neonatal resuscitation is effective ventilation. Little evidence exists to guide clinicians in their choice of manual ventilation device or face mask. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal resuscitation. AIM To compare the efficacy of (a) the Laerdal infant resu...

متن کامل

Effects of ventilator settings, nebulizer and exhalation port position on albuterol delivery during non-invasive ventilation: an in-vitro study

BACKGROUND Few studies have investigated the factors affecting aerosol delivery during non-invasive ventilation (NIV). Our aim was to investigate, using a bench-top model, the effect of different ventilator settings and positions of the exhalation port and nebulizer on the amount of albuterol delivered to a lung simulator. METHODS A lung model simulating spontaneous breathing was connected to...

متن کامل

Treatment of severe cardiogenic pulmonary edema with continuous positive airway pressure delivered by face mask.

BACKGROUND Severe cardiogenic pulmonary edema is a frequent cause of respiratory failure, and many patients with this condition require endotracheal intubation and mechanical ventilation. We investigated whether continuous positive airway pressure delivered by means of a face mask had physiologic benefit and would reduce the need for intubation and mechanical ventilation. METHODS We randomly ...

متن کامل

Aerosol bronchodilator therapy during noninvasive positive-pressure ventilation: a peek through the looking glass.

Exacerbations of chronic obstructive pulmonary disease (COPD) are a common cause of acute respiratory failure,1 leading to over 700,000 hospitalizations annually in the United States.2 Approximately 50% of patients suffering hypercapnic respiratory failure from exacerbations of COPD require some form of ventilatory support.3 The ventilatory strategy employed in such patients has evolved during ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 52 2  شماره 

صفحات  -

تاریخ انتشار 1997