Perfusion index as a predictor of hypotension following spinal anaesthesia in lower segment caesarean section

نویسندگان

  • Devika Rani Duggappa
  • MPS Lokesh
  • Aanchal Dixit
  • Rinita Paul
  • RS Raghavendra Rao
  • P Prabha
چکیده

BACKGROUND AND AIMS Perfusion index (PI) is a new parameter tried for predicting hypotension during spinal anaesthesia for the lower segment caesarean section (LSCS). This study aimed at investigating the correlation between baseline perfusion index and incidence of hypotension following SAB in LSCS. METHODS In this prospective observational study, 126 parturients were divided into two groups on the basis of baseline PI. Group I included parturients with PI of ≤3.5 and Group II, parturients with PI values >3.5. Spinal anaesthesia was performed with 10 mg of injection bupivacaine 0.5% (hyperbaric) at L3-L4 or L2-L3 interspace. Hypotension was defined as mean arterial pressure <65 mmHg. Statistical analysis was performed using Chi-square test, independent sample t-test and Mann-Whitney U-test. Regression analysis with Spearman's rank correlation coefficient was done to assess the correlation between baseline PI and hypotension. Receiver operating characteristic (ROC) curve was plotted for PI and occurrence of hypotension. RESULTS The incidence of hypotension in Group I was 10.5% compared to 71.42% in Group II (P < 0.001). There was significant correlation between baseline PI >3.5 and number of episodes of hypotension (rs0.416, P < 0.001) and total dose of ephedrine (rs0.567, P < 0.001). The sensitivity and specificity of baseline PI of 3.5 to predict hypotension was 69.84% and 89.29%, respectively. The area under the ROC curve for PI to predict hypotension was 0.848. CONCLUSION Baseline perfusion index >3.5 is associated with a higher incidence of hypotension following spinal anesthesia in elective LSCS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perfusion index derived from a pulse oximeter can predict the incidence of hypotension during spinal anaesthesia for Caesarean delivery.

BACKGROUND Hypotension during spinal anaesthesia for Caesarean delivery is a result of decreased vascular resistance due to sympathetic blockade and decreased cardiac output due to blood pooling in blocked areas of the body. Change in baseline peripheral vascular tone due to pregnancy may affect the degree of such hypotension. The perfusion index (PI) derived from a pulse oximeter has been used...

متن کامل

The predictive ability of non-invasive haemodynamic parameters for hypotension during caesarean section: a prospective observational study.

Spinal anaesthesia for caesarean section induces hypotension, which may cause severe adverse effects. Our goal was to determine whether hypotension could be predicted by pulse oximetry parameters, such as the perfusion index and pleth variability index, heart rate, ratio of low-frequency to high-frequency components of heart rate variability, and entropy of heart rate variability, measured befo...

متن کامل

Changes in pleth variability index and detection of hypotension during spinal anaesthesia for caesarean section.

Background: Hypotension occurs commonly during caesarean section under spinal anaesthesia. As the onset may be rapid, it may fail to be detected by non-invasive blood pressure (BP) measurement in a timely fashion. Pulse oximeters can continuously and non-invasively measure tissue perfusion (perfusion index (PI)) and its variation with the respiratory cycle (pleth variability index (PVI)). As wi...

متن کامل

Ventilatory management of severe acute respiratory failure for Y2K.

condition of mother and infant at cesarean section. Anesth Analg 1969; 48:986–93 8. Clark RB, Thompson DS, Thompson CH: Prevention of spinal hypotension associated with cesarean section. ANESTHESIOLOGY 1976; 45:670–4 9. Russell IF: Effect of posture during the induction of subarachnoid analgesia for caesarean section. Right v left lateral. Br J Anaesth 1987; 59:342–6 10. Norris MC: Hypotension ...

متن کامل

مقایسه اثر بوپیواکائین و لیدوکائین اینتراتکال بر میزان بروز افت فشار خون و تهوع واستفراغ در سزارین

        Aim and Background:   Hypotension and nausea are common side effects during spinal anesthesia. This study compared the incidence of hypotension and nausea-vomiting induced by bupivacaine and lidocaine in parturients undergoing caesarean section under spinal anaesthesia. Methods and Materials:   In this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 61  شماره 

صفحات  -

تاریخ انتشار 2017