Stability indicating high performance thin-layer chromatographic method for simultaneous estimation of pantoprazole sodium and itopride hydrochloride in combined dosage form

نویسندگان

  • Deepak Bageshwar
  • Vineeta Khanvilkar
  • Vilasrao Kadam
چکیده

A specific, precise and stability indicating high-performance thin-layer chromatographic method for simultaneous estimation of pantoprazole sodium and itopride hydrochloride in pharmaceutical formulations was developed and validated. The method employed TLC aluminium plates precoated with silica gel 60F254 as the stationary phase. The solvent system consisted of methanol:water:ammonium acetate; 4.0:1.0:0.5 (v/v/v). This system was found to give compact and dense spots for both itopride hydrochloride (Rf value of 0.55±0.02) and pantoprazole sodium (Rf value of 0.85±0.04). Densitometric analysis of both drugs was carried out in the reflectance-absorbance mode at 289 nm. The linear regression analysis data for the calibration plots showed a good linear relationship with R2=0.9988±0.0012 in the concentration range of 100-400 ng for pantoprazole sodium. Also, the linear regression analysis data for the calibration plots showed a good linear relationship with R2=0.9990±0.0008 in the concentration range of 200-1200 ng for itopride hydrochloride. The method was validated for specificity, precision, robustness and recovery. Statistical analysis proves that the method is repeatable and selective for the estimation of both the said drugs. As the method could effectively separate the drug from its degradation products, it can be employed as a stability indicating method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability-Indicating LC Method for Simultaneous Estimation of Rabeprazole Sodium Hydrochloride and Itopride Hydrochloride in Combined Dosage Form

A simple, sensitive and precise stability indicating HPLC method has been developed for the estimation of rabeprazole and itopride in combined dosage form. A Phenomenex Gemini C-18, 5 μm column with a mobile phase containing 0.02 M ammonium acetate (pH 6): acetonitrile: methanol (45: 20: 35, v/v/v) was used. The flow rate was 1.0 mL min and effluents were monitored at 284 nm. Rabeprazole and it...

متن کامل

Application of hydrotropic solubilization in spectrophotometric analysis of Esomeprazole and Itopride pharmaceutical combined tablet dosage forms

Two simple, accurate and precise methods for simultaneous estimation of Esomeprazole and Itopride in bulk drug and tablet dosage form have been described. Method-A employs formation and solving of simultaneous equation using 231 and 370 nm as two analytical wavelengths. Method -B is Absorption ratio method, which uses 308 and 331 nm as two analytical wavelengths.Beer’s law was obeyed in the con...

متن کامل

Quantitative Estimation of Itopride Hydrochloride and Rabeprazole Sodium from Capsule Formulation

Two simple, accurate, economical and reproducible UV spectrophotometric methods and one HPLC method for simultaneous estimation of two component drug mixture of itopride hydrochloride and rabeprazole sodium from combined capsule dosage form have been developed. First developed method involves formation and solving of simultaneous equations using 265.2 nm and 290.8 nm as two wavelengths. Second ...

متن کامل

Development And Validation Of HPTLC Method For Simultaneous Determination Of Tolperisone Hydrochloride And Diclofenac Sodium In Combined Dosage Form

1. Abstract: A new, simple, precise, accurate and selective high performance thin-layer chromatographic (HPTLC) method has been developed and validated for the simultaneous determination of Tolperisone hydrochloride and Diclofenac sodium in a tablet dosage form. Chromatographicseparation was carried out on Merck TLC aluminium sheets of silica gel 60F254 using Toluene: Ethyl acetate: Methanol (4...

متن کامل

High Performance Thin Layer Chromatographic Method for Simultaneous Estimation of Ibuprofen and Pseudoephedrine Hydrochloride

High performance thin layer chromatographic method is developed for simultaneous estimation of ibuprofen and pseudoephedrine hydrochloride in tablets. Silica gel 60F(254) plates were used as stationary phase and t.butanol: ethyl acetate: glacial acetic acid: water (7:4:2:2 v/v) as mobile phase. Wavelength selected for analysis was 254 nm. Percent estimation of ibuprofen and pseudoephedrine hydr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2011