Validation of A Semi-flexible 64-channel Receive-only Phased Array For Pediatric Body MRI at 3T

نویسندگان

  • Tao Zhang
  • Joseph Y Cheng
  • Paul D Calderon
  • Thomas Grafendorfer
  • Greig Scott
  • Bob Rainey
  • Mark Giancola
  • Fraser Robb
  • John M Pauly
  • Brian A Hargreaves
  • Shreyas S Vasanawala
چکیده

Purpose: Pediatric MRI is often performed using receive coils designed for adult patients. The mismatch of the receive coils and the pediatric patients can cause degraded image quality [1]. In this work, a 64-channel receive-only phased array dedicated for pediatric body MRI is designed and constructed. This coil array incorporates the quarter-wavelength-balun technique, achieves ideal coil decoupling, and conforms to different pediatric patient sizes. Here, we validated the performance and flexibility of the coil array in phantom and in vivo studies. Methods: The 64ch phased array (Fig 1) contains a 32ch anterior coil and a 32ch posterior coil embedded in the patient table. The quarter-wavelengthbalun technique is used to replace individual baluns [2]. Individual coils only overlap in the S/I direction, which creates high flexibility in the nonoverlapping (transverse) direction. To verify the coil decoupling and flexibility of the designed coil array, three different foam supports (Fig 2a) were designed to achieve 10°, 20° and 30° bending of the 32ch anterior coil. This simulates different matching scenarios of the receive coils and patient sizes. A 9”-diameter saline phantom was imaged on a GE 3T MR750 scanner using the 32ch anterior coil placed on the foam supports. For each bending scenario, a 2D spin echo sequence was performed. Normalized noise correlation matrix of the anterior 32 elements was calculated [3]. The datasets were retrospectively undersampled by factors of 2, 3, 4, and 5 in the phase encoding direction, and the corresponding g-factor was calculated. With IRB approval, two in vivo studies were performed. The first study was performed on a 30-year-old subject with breath-holding using a RF-spoiled gradient echo sequence with both the 64ch pediatric coil and product 32ch cardiac coil. The second study was performed on an 18-month-old subject free-breathing using the upper 32 elements of the 64ch pediatric coil. Results: The sum of squares images are shown in Fig 2a. As the coil gets closer to the phantom, higher SNR was observed in the image. This demonstrates the advantages of flexible coils conforming to patient size and shape. The noise correlation matrices are shown in Fig 2a. The max and mean value of the noise correlation did not vary much in different scenarios, which demonstrates good coil decoupling. The g-factor maps with different acceleration factors are shown in Fig 2b. As the anterior peripheral elements tilted more towards the phantom, the g-factor decreased, especially under higher acceleration in the lower part of the phantom, where coil sensitivity variations were small. This also suggests that better parallel imaging performance can be expected when the coil array matches the patient size. Images from in vivo studies are shown in Fig 3. Similar image quality was observed for the first study using two different coils. Excellent image quality was achieved for the second study using the 64ch pediatric coil. Conclusion: In this work, we have developed and validated a flexible 64-channel receive-only phased array for pediatric body MRI at 3T. References: [1] Vasanawala S, et al. ISMRM 2011, p161. [2]. Grafendorfer T, et al. ISMRM 2014, p1319. [3] Schmitt M. Magn Reson Med 2008; 59: 1431-1439. Fig 1. (a) Anterior 32 elements of the flexible coil before packaging: individual elements only overlap in the S/I direction, yielding high flexibility in the non-overlapping direction. Comparison of the anterior elements from a 32ch cardiac coil (b) and the 64ch pediatric coil (c) on a pediatric patient model demonstrates the flexibility of the 64ch pediatric coil.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 32-channel Receive Array Coil for Pediatric Brain Imaging at 3T

Introduction: Pediatric MRI currently requires general anesthesia to preclude motion artifacts. With highly accelerated image encoding in conjunction motion navigators it may be possible to significantly reduce or even eliminate anesthesia. For research studies of brain development where anesthesia is not possible, improved motion robustness can significantly improve the success rate. Highly pa...

متن کامل

MR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils

Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array "receive" coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal...

متن کامل

Influence of a Receive-array Coil on Specific Absorption Rate at 3T: Simulations and Experiments with Basic Geometries

Introduction: Receive-only (Rx) phased-array coils are used routinely in clinical situations for a number of purposes including achieving higher SNR [1] and shorter imaging times [2], but how their presence affects the RF field distribution during transmission is not routinely considered. At a minimum, the receive array introduces highly conductive surfaces with their associated boundary condit...

متن کامل

Feasibility of imaging superficial palmar arch using micro-ultrasound, 7T and 3T magnetic resonance imaging

AIM To demonstrate feasibility of vessel wall imaging of the superficial palmar arch using high frequency micro-ultrasound, 7T and 3T magnetic resonance imaging (MRI). METHODS Four subjects (ages 22-50 years) were scanned on a micro-ultrasound system with a 45-MHz transducer (Vevo 2100, VisualSonics). Subjects' hands were then imaged on a 3T clinical MR scanner (Siemens Biograph MMR) using an...

متن کامل

Prostate MRI and MRS at 3T: Using Phased Surface Coil Array

H. Mao, X. Hu, K. Heberlein, R. Smith, W. Torres Department of Radiology, Emory University School of Medcine, Atlanta, Georgia, United States, Department of Biomedical Enginnering, Emory University School of Medcine, Atlanta, Georgia, United States, Georgia Institute of Technology, Atlanta, Georgia, United States INTRODUCTION Prostate cancer is the most common cancer and the second most frequen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014