Clinical evaluation of Guido robotic walker.

نویسندگان

  • Andrew J Rentschler
  • Richard Simpson
  • Rory A Cooper
  • Michael L Boninger
چکیده

The Guido is a robotic walker that provides navigation and obstacle-avoidance assistance. Engineering tests have found that the device performs adequately and presents no hazard to the user. The performance of the Guido was compared with a low-tech mobility aid, the Assistive Mobility Device (AMD) developed at the Atlanta Department of Veterans Affairs Medical Center, in trials involving older adults with visual impairments. The purpose of this study was to determine whether the Guido could increase the safety and mobility of elderly visually impaired individuals in supervised care facilities. Subjects traversed an obstacle course with the Guido and the AMD. Completion time, obstacle/wall contacts, and reorientations were compared for both devices. No significant differences were found between the devices for any of the tests. The Guido did not perform better than the AMD during the trials. Revisions to the device as well as a change in subject requirements and testing protocol may produce different results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging

This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...

متن کامل

Laboratory Methodologic Approach in Prolonged Activated Partial Thromboplastin Time Test

The pathological activated partial thromboplastin time test is a data that we can find in all clinical laboratories routinely. The hemato-coagulative clinical case here reported aims to point out how the laboratory can provide a correct diagnosis by methodological rational setting and, consequently, carry out an appropriate therapy, or reassure the patient that the pathological data will not ca...

متن کامل

Evaluation of the Performance of CS Freiburg 1999 and CS Freiburg 2000

One of the questions one may ask when following research in robotic soccer is whether there is a measurable progress over the years in the robotic leagues. While everybody who has followed the games from 1997 to 2000 would agree that the robotic soccer players in the F2000 league have improved their playing skills, there is no hard evidence to justify this opinion. We tried to identify a number...

متن کامل

Lab#7: Robotic walker survey paper

Next generation Robotic Walker designers are investigating navigation functions to help the elderly and disabled people to remain healthier and stay socially active. However, unattended safety concern will highly likely led to a drop in users’ acceptance and organizational uptake of this technique. If safety remains to be a concern of both carers and users, this technique will possibly be at a ...

متن کامل

Design of an Active Walking-aid for Elderly People

This paper describes the preliminary design of a light, high stability, robotic system for elderly assistance. The mechanisms used for such assisting devices must exhibit complex mechanical functions that may change during the use. The design has also to be adapted to the morphology and/or pathology. Taking these constraints into account, the design of a robotic walker is presented which provid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 45 9  شماره 

صفحات  -

تاریخ انتشار 2008