Comparison of the safety of drug delivery via HFA- and CFC-metered dose inhalers in CAO.

نویسندگان

  • G Huchon
  • P Hofbauer
  • G Cannizzaro
  • P Iacono
  • F Wald
چکیده

The objective of this study was to compare the long-term safety of a fixed combination of fenoterol hydrobromide (50 microg) and ipratropium bromide (20 microg) delivered using a metered dose inhaler (MDI) formulated with a non-chlorinated propellant, hydrofluoroalkanel34a (HFA-MDI), with delivery using the conventional chlorofluorocarbon propellant (CFC-MDI, Berodual/Bronchodual). The study was designed according to Safety Assessment of Marketed Medicines (SAMM) guidelines, to reflect as far as possible the use of MDls under normal prescribing conditions. Two thousand and twenty-seven patients with chronic airways obstruction (CAO) were enrolled from 99 centres in France, 95 centres in Germany and 24 centres in Italy. Following a 2-week run-in period, patients were randomized on a 2:1 basis (1,348 patients to HFA-MDI, 679 patients to CFC-MDI) to receive a flexible dose regimen of the combination (2 puffs, 2-4 times a day, as prescribed by the investigator) during a 12-week open label phase. The overall incidence of adverse events was comparable between both groups. In addition, the incidence of respiratory side effects was also similar, with CAO exacerbations or bronchitis the most frequently recorded events. The safety profile of the HFA formulation was comparable to those of the marketed CFC-MDIs used in Germany and France/Italy. No clinically significant differences were detected between HFA134a or CFC driven inhalers on the switch from CFC- to HFA-MDI (2 weeks before randomisation versus 2 weeks after randomization). There was a trend for taste complaints to be reported more frequently by patients in the HFA-MDI group (0.7% before randomization versus 3.4% after randomization). This, however, was an expected finding as the HFA134a formulation does have a different taste to the CFC formulation. No difference between formulations was observed in the incidences of coughing or paradoxical bronchospasm. The incidence of falls in FEV1 >15% within 15 min following inhalation at each of the clinic visits was 1.2% for both CFC- and HFA-MDIs. In conclusion, administration of a fenoterol/ipratropium bromide combination via hydrofluoroalkane-metered dose inhaler is as safe as delivery by the currently available chlorofluorocarbon-metered dose inhaler, in an extended population of patients with CAO under normal prescribing conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The CFC to HFA transition and its impact on pulmonary drug development.

The terms of the Montreal Protocol have eliminated chlorofluorocarbons (CFCs) and other ozone-depleting agents from commercial use, with the exemption of their use as propellants in metered-dose inhalers. Two new propellants have been approved for CFC substitutes: hydrofluoroalkane (HFA)-134a and HFA-227. An extensive safety program was conducted by the International Pharmaceutical Aerosol Cons...

متن کامل

Inhaled corticosteroid delivery systems: clinical role of a breath-actuated device.

Several devices have been developed to overcome the need to co-ordinate actuation with inhalation required during use of a pressurised metered dose inhaler (MDI) and to improve drug delivery to the lung. These include spacer attachments for MDIs, dry powder inhalers and breath-actuated MDIs. The breath-actuated Autohaler (3M Pharmaceuticals) is a compact, multidose inhaler device that, unlike d...

متن کامل

A comparison of HFA-BDP Autohaler with budesonide Turbuhaler in asthma control of adult patients with mild to moderately severe disease.

Hydrofluoroalkane-134a (HFA) beclomethasone dipropionate (BDP) extrafine aerosol is a pressurized metered dose inhaler (pMD1) available for the treatment of asthma. Unlike most pMDIs, HFA-BDP is a solution, rather than a suspension, of BDP in HFA propellant. This reforrnulation, combined with improvements in inhaler technology, results in the production of aerosol particles of smaller mean mass...

متن کامل

Factors affecting the efficiency of aerosol therapy with pressurised metered-dose inhalers through plastic spacers.

AIM The main objective of this study was to compare the in vitro delivery of salbutamol from a chlorofluorocarbon(CFC)-propelled pressurised metered-dose inhaler (pMDI) versus a newly developed hydrofluoroalkane(HFA)-propelled pMDI through various spacers. In addition, we aimed to study the effect on bronchodilator response when using an optimal pMDI/spacer combination for aerosol delivery comp...

متن کامل

Inhaled corticosteroids for adult asthma: impact of formulation and delivery device on relative pharmacokinetics, efficacy and safety.

Metered dose inhalers (MDIs) are the mainstay of inhaled steroid therapy for asthma. With the phasing out of traditional chlorofluorocarbon (CFC) propellants and their replacement with a new generation of CFC-free products, it is becoming clear that formulation and inhaler characteristics can markedly affect the drug delivery. It now seems necessary to compare inhalers not only on the basis of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2000