Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation.

نویسندگان

  • Eric Strauss
  • Joshua Frank
  • Jason Lee
  • Frederick J Kummer
  • Nirmal Tejwani
چکیده

OBJECTIVE To compare the fixation stability in the femoral head with sliding hip screw versus helical blade designs for unstable, intertrochanteric hip fractures. METHODS A simulated, unstable intertrochanteric hip fracture was created in six pairs of cadaveric femurs. One of each pair was treated using an intramedullary nail with a sliding hip screw (ITST) for femoral head fixation and the other was treated with a nail with a helical blade (TFN). Each specimen was cyclically loaded with 750N vertical loads applied for 10, 100, 1000 and 10,000 cycles. Measurements for femoral head displacement, fracture fragment opening and sliding were made. Specimens were then loaded to failure. RESULTS There was significantly more permanent inferior femoral head displacement in the ITST samples compared to the TFN samples after each cyclic loading (all p values<0.05). There was significantly more permanent fracture site opening and inferior displacement in the ITST group compared with the TFN group at 1000 and 10,000 cycles (p<0.05). Final loads to failure were not significantly different (p=0.51) between the two treatment groups. Nine specimens demonstrated fracture extension into the anteromedial cortex and subtrochanteric region and three specimens, which had an ITST implant, demonstrated a splitting fracture of the femoral head. CONCLUSION This study demonstrated that fixation of the femoral head with a helical blade was biomechanically superior to fixation with a standard sliding hip screw in a cadaveric, unstable intertrochanteric hip fracture model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Biomechanical Study Comparing Helical Blade with Screw Design for Sliding Hip Fixations of Unstable Intertrochanteric Fractures

Dynamic hip screw (DHS) is a well-established conventional implant for treating intertrochanteric fracture. However, revision surgery sometimes still occurs due to the cutting out of implants. A helical blade instead of threaded screw (DHS blade) was designed to improve the fixation power of the osteoporotic intertrochanteric fracture. In this study, the biomechanical properties of DHS blade co...

متن کامل

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...

متن کامل

Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures

Fixation with a dynamic hip screw (DHS) is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('B...

متن کامل

Commentary: Morphology and fixation pitfalls of a highly unstable intertrochanteric fracture variant.

fractures with an intact posteromedial buttress, have been successfully treated with a sliding hip screw or blade.1 However, unstable intertrochanteric fractures tend to collapse even after adequate reduction and fixation with plating, and thus intramedullary nailing is recommended.2 Unstable intertrochanteric fractures include fractures with posteromedial comminution, a reverse oblique configu...

متن کامل

Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures – postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate

BACKGROUND In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Injury

دوره 37 10  شماره 

صفحات  -

تاریخ انتشار 2006