Doppler Assessment of Prosthetic Valve Orifice Area

نویسندگان

  • Helmut Baumgartner
  • Steven S. Khan
  • Michele DeRobertis
چکیده

Background. Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. Methods and Results. Doppler-estimated valve areas were studied for their agreement with catheterderived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-27 mm) of St. Jude, Medtronic-Hall, and Hancock aortic valves using a pulsatile flow model. Doppler areas were calculated three ways: using the standard continuity equation; using its simplified modification (peak flow/peak velocity); and using the Gorlin equation with Doppler pressure gradients. The results were compared with Gorlin effective orifice areas derived from direct flow and catheter pressure measurements. Excellent correlation between Gorlin effective orifice areas and the three Doppler approaches was found in all three valve types (r=0.93-0.99, SEE=0.07-0.11 cm2). In Medtronic-Hall and Hancock valves, there was only slight underestimation by Doppler (mean difference, 0.003-0.25 cm2). In St. Jude valves, however, all three Doppler methods significantly underestimated effective orifice areas derived from direct flow and pressure measurements (mean difference, 0.40-0.57 cm2) with differences as great as 1.6 cm2. In general, the modified continuity equation calculated the largest Doppler areas. When orifice areas were calculated from the valve geometry using the area determined from the inner valve diameter reduced by the projected area of the opened leaflets, Gorlin effective orifice areas were much closer to the geometric orifice areas than Doppler areas (mean difference, 0.40±0.31 versus 1.04±0.20 cm2). In St. Jude and Medtronic-Hall valves, areas calculated by either technique did not show a consistent or clinically significant flow dependence. In Hancock valves, however, areas calculated by both the continuity equation and the Gorlin equation decreased significantly (p<0.001) with low flow rates. Conclusions. Doppler echocardiography using either the continuity equation or Gorlin formula allows in vitro calculation of Medtronic-Hall and Hancock effective valve orifice areas but underestimates valve areas in St. Jude valves. This phenomenon is due to localized high velocities in St. Jude valves, which do not reflect the mean velocity distribution across the orifice. Valve areas are flow independent in St. Jude and Medtronic-Hall prostheses but decrease significantly with low flow in Hancock valves, suggesting that bioprosthetic leaflets may not open fully at low flow rates. (Circulation 1992;85:2275-2283)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler assessment of prosthetic valve orifice area. An in vitro study.

BACKGROUND Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. METHODS AND RESULTS Doppler-estimated valve areas were studied for their agreement with catheter-derived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-...

متن کامل

Application of color Doppler flow mapping to calculate orifice area of St Jude mitral valve.

BACKGROUND The effective orifice area (EOA) of a prosthetic valve is superior to transvalvular gradients as a measure of valve function, but measurement of mitral prosthesis EOA has not been reliable. METHODS AND RESULTS In vitro flow across St Jude valves was calculated by hemispheric proximal isovelocity surface area (PISA) and segment-of-spheroid (SOS) methods. For steady and pulsatile con...

متن کامل

Doppler echocardiographic evaluation of prosthetic valve function.

Owing to its versatile, non-invasive, radiation-free, and low cost nature, Doppler echocardiography is undoubtedly the method of choice to evaluate prosthetic valve function. This evaluation follows the same principles used for the evaluation of native valves, with some important specifics and caveats described in this article. A complete echocardiography includes two dimensional imaging of the...

متن کامل

Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...

متن کامل

Assessment of severity of mechanical prosthetic mitral regurgitation by transoesophageal echocardiography.

OBJECTIVE To evaluate the ability of colour Doppler transoesophageal echocardiography (TOE) to assess quantitatively prosthetic mitral valve insufficiency. METHODS 47 patients were studied with multiplane TOE and cardiac catheterisation. Proximal jet diameter was measured as the largest diameter of the vena contracta. Regurgitant area was measured by planimetry of the largest turbulent jet du...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005