Effects of instrument settings on radiofrequency ultrasound local estimator images: a preliminary study in a gallbladder model.

نویسندگان

  • Jian Wang
  • Chunsong Kang
  • Tinghua Feng
  • Jiping Xue
  • Kailing Shi
  • Tingting Li
  • Xiaofang Liu
  • Yu Wang
چکیده

The aim of the present study was to evaluate the changes in radiofrequency ultrasound local estimator (RULES) images with different instrument settings. An Esaote Technos MPX Color Doppler Ultrasound Machine and RULES were used to capture images of a gallbladder model. The percentages of various colored areas (color filling rates) within the area of interest were calculated using different instrument gains, transducer frequencies and scan depths. Blue was predominant in the lumen of the model gallbladder, while red and green were primarily located near the inner edge of the lumen. When the depth was set at 62 mm and the gain at 105, the total color filling rates did not vary with different transducer frequencies. The blue color filling rate was greatest with a transducer frequency of 8.0 MHz, and the red and green color filling rates were greatest with a frequency of 12.5 MHz. Color variety was greatest when the transducer frequency was 12.5 MHz. When the transducer frequency was 12.5 MHz and the depth was 62 mm, the blue color filling rate was greatest with gains of 105 and 110, the red color filling rate was greatest with gains of 95 and 100 and the green color filling rate was greatest when the gain was 100. The total color filling rate was greatest at gains of 100 and 105. In conclusion, images obtained using RULES may be affected by the instrument gain and, to a certain extent, by transducer frequency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative brightness due to temperature changes with ultrasound image analysis during Radiofrequency ablation

Introduction: Diagnosis of primary and secondary cancers to treat patients with diffuse and malignant tumors is an important subject. The appropriate treatment will be eliminating primary and metastatic tumors. Radiofrequency ablation with localized heat induction in the target tissue causes irreversible cellular damage and tissue coagulation. Estimation of tissue temperature c...

متن کامل

An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation

Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...

متن کامل

Positive-Shrinkage and Pretest Estimation in Multiple Regression: A Monte Carlo Study with Applications

Consider a problem of predicting a response variable using a set of covariates in a linear regression model. If it is a priori known or suspected that a subset of the covariates do not significantly contribute to the overall fit of the model, a restricted model that excludes these covariates, may be sufficient. If, on the other hand, the subset provides useful information, shrinkage meth...

متن کامل

Temperature Mapping Using Ultrasound Digital Images

Introduction:  The  success  of  hyperthermia  depends  on  the  accuracy  of  the  temperature  monitoring in the tumor and the surrounding normal tissue. In this study, the temperature changes  were determined by computing the speckle displacement in the ultrasound digital images. Speckle  tracking algorithm was used to compute the displacement.  Materials and Methods: The experiment was perf...

متن کامل

Design, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging

This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Molecular medicine reports

دوره 8 4  شماره 

صفحات  -

تاریخ انتشار 2013