Objective: To identify perioperative clinical predictors of permanent pacemaker implantation following aortic valve replacement. Design and patients: Prospective cohort study on 276 patients submitted for aortic valve replacement: 267 patients (mean (SD) age, 57.5 (14) years) with no conduction disturbances, and nine patients (67.7 (5) years) with severe conduction disturbances requiring permanent pacing; 65 perioperative variables (38 preoperative, eight intraoperative, and 19 postoperative) were considered. Results: Nine patients (3.2%) had irreversible second or third degree atrioventricular (AV) block requiring permanent pacing. Risk factors for permanent pacing identified by univariate analysis were: preoperative: additional valvar disease, aortic regurgitation, myocardial infarction, pulmonary hypertension, anaemia, use of digitalis; intraoperative: cardiac arrest; postoperative: cardiac arrest, conduction disturbances, electrolytic imbalance, angiotensin converting enzyme inhibitor use. Multivariate logistic regression analysis identified preoperative aortic regurgitation (p < 0.005; odds ratio (OR) 6.6, 95% confidence interval (CI) 1.6 to 12.2), myocardial infarction (p < 0.0005; OR 15.2, 95% CI 6.3 to 19.9), pulmonary hypertension (p < 0.005; OR 12.5, 95% CI 3.2 to 18.3), and postoperative electrolyte imbalance (p < 0.01; OR 4.5, 95% CI 1.3 to 6.4). Conclusions: Irreversible AV block requiring permanent pacemaker implantation is an uncommon condition following aortic valve replacement. Previous aortic regurgitation, myocardial infarction, pulmonary hypertension, and postoperative electrolyte imbalance should be considered in order to identify patients at increased risk for advanced AV block.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

In patients undergoing aortic valve replacement, what factors predict the requirement for permanent pacemaker implantation?

A best evidence topic in cardiac surgery was written according to a structured protocol. The question was to determine what preoperative, perioperative and postoperative factors influence the requirement for permanent pacemaker (PPM) implantation postisolated aortic valve replacement (AVR). Transcatheter aortic valve intervention was not included in this analysis. Using the reported search meth...

متن کامل

Patient selection for transcatheter aortic valve implantation: An interventional cardiology perspective.

Transcatheter aortic valve implantation (TAVI) has emerged as a highly effective minimally invasive treatment symptomatic for severe calcific aortic stenosis in patients at high or prohibitive surgical risk. The success of TAVI has been determined by a number of factors, but in particular by appropriate patient selection. Appropriate patient selection involves identifying patients with the pote...

متن کامل

INTERVENTIONAL CARDIOLOGY AND SURGERY Incidence of embolism and paravalvar leak after St Jude Silzone valve implantation: experience from the Cardiff Embolic Risk Factor Study

Background: Silver coating of the sewing ring (Silzone) was introduced as a modification of the St Jude Medical standard valve to provide antibacterial protection, but the valve has recently been withdrawn. Objective: To study patients with these prostheses to assess possible adverse effects, and to guide their follow up. Design: Prospective observational study of risk factors for stroke after ...

متن کامل

Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.

BACKGROUND Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pace...