Design Parameters for Fuel Batteries

نویسندگان

  • A. P. HARDT
  • M. COTA
  • T. KATAN
چکیده

Some design parameters of a hydrazine-oxygen fuel battery operating in a zero G field are described in a digital computer programming treatment. The power balance for a battery employing a gas-producing electrode and an electrolyte pump is treated; optimum power densities and flow rates are established. INTRODUCTION WITHIN the last decade fuel cell technology has advanced from the research stage to the development of hardware prototypes. Periods of alternating optimism followed by disillusionment have given way to the conviction that existing problems are amenable to solution by the same approach that has proven so successful in other engineering applications. Fuel cells, being electrochemical devices, suffer polarization; being chemical plants, they have waste products which must be removed; and being energy converters, they have heat-exchange problems. Each problem by itself is not unduly difficult but in combination with requirements of minimum bulk or mass coupled with maximum lifetime and reliability, they tax the ingenuity of the designer. Experience has shown that generally there exists quite a degree of latitude in the choice of design parameters, and the mutual dependence of the variables is not immediately obvious. In a recent computer analysisl on the performance of a fuel cell operating with gas-fed electrodes, the electrochemistry of fuel cell technology was reviewed, and the conclusion was reached that the net power level reached an optimum value chiefly determined by current density, being only slightly affected by electrolyte flow rate. Actual fuel cells employ porous electrodes which are quite insensitive to current density in the range of their operation. Furthermore, some systems tend to build up inhibiting phases which, by changing the effective conductance of the electrolyte, affect the cell voltage significantly, and the flow rate is then important. Such systems have been studied by us and this is a report on the digital computer analysis of our findings. This study is based on the hydrazine-oxygen system, N2H4(aq) +40H--+ N2(g) + 4H20 + 4e(1) 02(g) + 2H20 --+ 40H4e-. (2) The anode liberates gaseous nitrogen, equation (1), which tends to be removed spontaneously in a gravitational field giving rise to a convection current which in turn can be utilized for circulating the electrolyte. In the absence of gravity, the gas tends to accumulate in and around the electrodes, giving rise to a rapid drop in power output. Hence, convection must be supplied by external power which is also necessary to effect the separation of the two phases by a suitable device. The battery operates as follows. The anolyte is forced by a pump through a porous nickel electrode where it is oxidized. The two-phase spent electrolyte, diluted by the cathodically formed water, is separ'ated in a gas-liquid separator and partially dehydrated in an evaporator. The electrolyte is then stored in a tank where it may becooled further and replenished with fuel. Here the electrolyte flow rate and the power density are the independent variables if the desired power output of the cell is fixed. As the pumping power must be furnished by the unit itself, some optimum power density must exist which is determined by the flow rate and the current density. The choice of these parameters in an actual design will be further defined by the requirements of fuel efficiency and by the mission duration. This design study is restricted to optimization with respect to minimum cell volume alone. NOTATION A Superficial electrode area E Potential ep Pump efficiency void fraction f F Faraday constant 96,500 C/equivalent G Volumetric flow rate cm/min 11 Head loss cm of H.O I Current density A/cm' (, Effective conductance mho/cm IC, Conductance of electrolyte mho/cm L Equivalent length of pipes em f.I. Viscosity P n Number of cells PB,PU Pump power w Pc Cell power W Pressure atm P p Density of electrolyte g/cm R Gas constant l.-atm/g-mole. OK ,. Radius of pipes em T Temperature OK V Voltage Subscripts: e effective c cell H hydrazine K 30% KOH CALCULATIONS The power output of each cell is given by Po = I(V/ ~.6.Echem ~.6.Econc I ~) (3) The open-circuit potential of the hydrazine-oxygen fuel cell operating continuously with 0·2 M hydrazine in 30 per cent KOB electrolyte at 40°C is approximately 0·75 V. The apparent activation polarization is computed by the Tafel equation ilEchem = a + b log I (4) using the constants given in Table 1. For the purpose of this study the constants a and b must be thought of as being empirical constants only. TABLE 1. EXPERIMENTALLY DETERMINED CONSTANTS Electrode a V b V c V it A/cm' Porous nickel anode, black platinum plated 0·010 0'0038 0-40 0·295 Carbon cathode 2·5 x 10-5 2'25 x 10-4 0·0278 0·222 The apparent concentration polarization is computed by ilEcono = clog [JL/(IL I)], (5) where the values of the limiting current, h, are considered constant. This assumption is a reasonable one for porous electrodes which exhibit a substantially higher limiting current than solid electrodes, even though the limiting current is not very pronounced or reproducible due to the great variation of reaction rates within the pores. At the present stage of porous electrode technology the use of experimental performance characteristics is the most meaningful. The last term in equation (3) represents the voltage drop across the electrolyte, here expressed in terms of effective conductance which is affected by the void fraction, or volume fraction, occupied by the non-conducting phase,2 K. = KeO f)3/2. (6) The void fraction,j, is determined by the current and the electrolyte flow, j= IART/(4pFG + JART). (7) Fig. I shows the values of the effective conductance as a function of flow rate, with current density as a parameter. This treatment assumes the limiting case of generation of the void fraction at the entrance of the electrolyte. Fig. 2 shows the effect of the void fraction on cell voltage as a function of current density at varying flow rates. Evidently the cells polarize rapidly at the low flow rates. The same data are plotted in Fig. 3 showing that the cell voltage attains a plateau after the flow rate exceeds 200 cm3/min. By equation (3) these data can be utilized in the calculation of the power density. Fig. 4 shows the cell power as a function of flow rate where the rapid attainment of a plateau is again evident. Equally significant is the appearance of a maximum power density at approximately 0·16 AJcm2• Replotting these data on Fig. 5 results in the attainment of a series of maxima with insignificant gain in power density at higher flow rates. Laboratory tests with aged electrodes and well circulated electrolyte reproduce these data within experimental limits of accuracy.3

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fuel Cells and Flow Batteries - Chances and Challenges for Sustainable Energy Supply

The upcoming innovation of a sustainable energy supply and smart grids will clearly change the infrastructure of the global energy supply, distribution and use. One key issue is the increase of efficiency of energy utilization and energy conversion under the condition that the importance of electricity will further increase. The increasing amount of fluctuating renewable electric power generati...

متن کامل

Man-portable Power Generation Based on Fuel-cell Systems

Micro-fabricated fuel cell systems are a potential consumer product with the promise to outperform batteries for man-portable power generation in terms of the achievable energy density. A great variety of potential devices are being considered in various research institutions and thus there is a need for a systematic product design methodology, including comparison of alternatives and examinati...

متن کامل

Modeling Hybrid Energy Systems for Use in Auvs

Specifying an energy source for an AUV is usually a compromise between performance and cost. For most vehicles and most missions, high specific energy primary lithium batteries are not a practical option due to cost. One solution that shows promise and affordable cost is to use a hybrid approach that combines low cost secondary batteries with a fuel cell or combustion energy source. Exploring t...

متن کامل

Origami Paper-based Microbial Fuel Cells for Disposalble Biosensors

In this work, we created a stackable and integratable two-chambered paper-based microbial fuel cell (MFC) for potentially powering on-chip paper-based biosensors. By applying origami techniques, four batteries were connected in series to obtain an open-circuit voltage (1.6V) and a stable output current (4 μA). The bacterial cells flowed through patterned fluidic pathways within the paper matrix...

متن کامل

Design and testing of a fuel-cell powered battery charging station

The portable fuel-cell powered battery charging station provides a good solution to recharging batteries in field applications. This paper presents the design and testing of control strategies for this system using the Virtual Test Bed (VTB). The VTB provides a unique environment to model interdisciplinary components, to rapidly prototype the control system, and to simulate complex systems. In ...

متن کامل

Comparison between Batteries and Fuel Cells for Photovoltaic System Backup

Batteries and fuel cells contain a great potential to back up severe photovoltaic power fluctuations under inclement weather conditions. In this paper comparison between batteries and fuel cells is carried out in detail only for their PV power backup options, so their common attributes and different attributes is discussed. Then, the common and different attributes are compared; accordingly, th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008