Instantaneous quantification of skeletal muscle activation, power production, and fatigue during cycle ergometry.
نویسندگان
چکیده
A rapid switch from hyperbolic to isokinetic cycling allows the velocity-specific decline in maximal power to be measured, i.e., fatigue. We reasoned that, should the baseline relationship between isokinetic power (Piso) and electromyography (EMG) be reproducible, then contributions to fatigue may be isolated from 1) the decline in muscle activation (muscle activation fatigue); and 2) the decline in Piso at a given activation (muscle fatigue). We hypothesized that the EMG-Piso relationship is linear, velocity dependent, and reliable for instantaneous fatigue assessment at intolerance during and following whole body exercise. Healthy participants (n = 13) completed short (5 s) variable-effort isokinetic bouts at 50, 70, and 100 rpm to characterize baseline EMG-Piso. Repeated ramp incremental exercise tests were terminated with maximal isokinetic cycling (5 s) at 70 rpm. Individual baseline EMG-Piso relationships were linear (r(2) = 0.95 ± 0.04) and velocity dependent (analysis of covariance). Piso at intolerance (two legs, 335 ± 88 W) was ∼45% less than baseline [630 ± 156 W, confidence interval of the difference (CIDifference) 211, 380 W, P < 0.05]. Following intolerance, Piso recovered rapidly (F = 44.1; P < 0.05; η(2) = 0.79): power was reduced (P < 0.05) vs. baseline only at 0-min (CIDifference 80, 201 W) and 1-min recovery (CIDifference 13, 80 W). Activation fatigue and muscle fatigue (one leg) were 97 ± 55 and 60 ± 50 W, respectively. Mean bias ± limits of agreement for reproducibility were as follows: baseline Piso 1 ± 30 W; Piso at 0-min recovery 3 ± 35 W; and EMG at Piso 3 ± 14%. EMG power is linear, velocity dependent, and reproducible. Deviation from this relationship at the limit of tolerance can quantify the "activation" and "muscle" related components of fatigue during cycling.
منابع مشابه
The Effect of Skinfold on the Assessment of the Mean Power Frequency at the Fatigue Threshold
The purpose of this study was to determine if the amount of subcutaneous tissue over the quadriceps affects the assessment of mean power frequency at the fatigue threshold (MPFFT). It was hypothesized that greater skinfold values will result in lower power outputs associated to the MPFFT. Fourteen adults (Mean ± SD age = 20.7 ± 0.99; body weight = 72.8 ± 12.6 kg) performed an incremental cycle ...
متن کاملEffect of general fatigue on knee join muscle work and power absorption during stance phase of running
All sustained physical activities subject the body to various levels of fatigue. This is especially evident when running, which is one of the most popular forms of exercise and may be described as a reduction in maximum force production and power output . the purpose of this study was to investigate the effect of running in an exerted state on knee muscles power absorption and work during the ...
متن کاملAssessment of the Static Component of Aerobic Exercise: A Comparison of Exercise Using Cycle and Treadmill Ergometry, Hip Extension Exercises With or Without Gliding, and Gliding Video Workouts
Four subjects, whose ages averaged 24.3 years, were examined to assess the isometric component of dynamic exercise during the following 4 conditions: treadmill running, cycle ergometry, aerobic exercise following a video, and during hip extension exercise (lunges). The isometric component of exercise was characterized by examining heart rate (HR) and blood pressure (BP), muscle fatigue, oxygen ...
متن کاملHandgrip contribution to lactate production and leg power during high-intensity exercise.
PURPOSE The purpose of this study was to examine the upper-body contribution via handgrip to power profiles and blood lactate concentrations during high-intensity cycle ergometry. METHODS Nine trained male subjects each completed a 20-s high-intensity cycle ergometer test twice, in a random manner, using two protocols, with a handgrip (WG), and without handgrip (WOHG). Capillary (earlobe) blo...
متن کاملPower fatigue of the rat diaphragm muscle.
We hypothesized that decrements in maximum power output (W(max)) of the rat diaphragm (Dia) muscle with repetitive activation are due to a disproportionate reduction in force (force fatigue) compared with a slowing of shortening velocity (velocity fatigue). Segments of midcostal Dia muscle were mounted in vitro (26 degrees C) and stimulated directly at 75 Hz in 400-ms-duration trains repeated e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 118 5 شماره
صفحات -
تاریخ انتشار 2015