Endogenous carbon monoxide production in patients with hemolytic anemia.

نویسندگان

  • R F Coburn
  • W J Williams
  • S B Kahn
چکیده

It is desirable in many studies to be able to rapidly measure rates of erythrocyte and hemoglobin destruction. Labeling techniques have been utilized for this purpose but have the disadvantage of requiring several days' to weeks to obtain the desired data plus the hazards of radioactive isotopes. Estimations of hemoglobin turnover from measurements of fecal bile pigment or serum bilirubin concentrations contain large sources of error (1). Studies in which bile pigment is collected via bile duct fistulas have been of value in animal experiments (2) but are -not usually possible in man, and subjects who have bile fistulas cannot be called normal. At the present time it appears that many in vivo investigations of red cell survival in patients with hemolytic disease are limited by the lack of a precise rapid method for detecting changes in the rate of red cell destruction. It has been shown previously (3-9) that CO is an in vivo catabolic by-product of hemoglobin and

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbon monoxide production associated with ineffective erythropoiesis.

The rate of endogenous carbon monoxide production ( Vco), determined by the closed rebreathing system technique, was elevated above the normal range in four of five patients studied with ineffective erythropoiesis (four patients with primary refractory anemia, one with thalassemia). The mean molar ratio of Vco to Vheme (rate of circulating heme catabolism, determined from (51)Cr red cell surviv...

متن کامل

Quantitative Immunology of Immune Hemolytic Anemia

INTRODUCTION The commonest form of autoimmune hemolytic anemia is characterized by the presence of antibody of the IgG immunoglobulin class on the red cell (1). These antibodies characteristically react with red cell antigens at body temperature, and they fix complement relatively inefficiently since two antibody molecules in juxtaposition are required to initiate a complement sequence (2). The...

متن کامل

Effect of blood in the gut on measurements of endogenous carbon monoxide production.

Changes induced in measurements of endogenous carbon monoxide (CO) production by blood in the lumen of the gut were studied in five normal volunteers. The study was undertaken because exogenous heme is absorbed by intestinal mucosal cells where the porphyrin ring is split with the release of CO that could contribute to blood CO levels and lead to a fallacious diagnosis of hemolytic disease. Vol...

متن کامل

The measurement of endogenous carbon monoxide production.

Recent findings that heme oxygenase-1 can be induced by oxidative stress and inflammation in many different cellular systems, and that carbon monoxide (CO) produced as a by-product of this enzyme is a signaling molecule, have generated a major research area with hundreds of studies published over the last few years. The measurement of expired CO concentration has been used in humans as a biomar...

متن کامل

Corticosteroid-Responsive Pulmonary Toxicity Associated with Fludarabine Monophosphate: A Case Report

UNLABELLED Fludarabine monophosphate is an effective drug for the treatment of lymphoid malignancies. Myelosuppression, opportunistic infections, and autoimmune hemolytic anemia are the most common side effects of fludarabine. Herein we report a 55-year-old female that presented with fever and dyspnea after completing her third cycle of FMD (fludarabine, mitoxantrone, and dexamethasone) chemoth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of clinical investigation

دوره 45 4  شماره 

صفحات  -

تاریخ انتشار 1966