Digital breast tomosynthesis: a pilot observer study.
نویسندگان
چکیده
OBJECTIVE The objective of our study was to assess ergonomic and diagnostic performance-related issues associated with the interpretation of digital breast tomosynthesis-generated examinations. MATERIALS AND METHODS Thirty selected cases were read under three different display conditions by nine experienced radiologists in a fully crossed, mode-balanced observer performance study. The reading modes included full-field digital mammography (FFDM) alone, the 11 low-dose projections acquired for the reconstruction of tomosynthesis images, and the reconstructed digital breast tomosynthesis examination. Observers rated cases under the free-response receiver operating characteristic, as well as a screening paradigm, and provided subjective assessments of the relative diagnostic value of the two digital breast tomosynthesis-based image sets as compared with FFDM. The time to review and diagnose each case was also evaluated. RESULTS Observer performance measures were not statistically significant (p > 0.05) primarily because of the small sample size in this pilot study, suggesting that showing significant improvements in diagnosis, if any, will require a larger study. Several radiologists did perceive the digital breast tomosynthesis image set and the projection series to be better than FFDM (p < 0.05) for diagnosing this specific case set. The time to review, interpret, and rate the examinations was significantly different for the techniques in question (p < 0.05). CONCLUSION Tomosynthesis-based breast imaging may have great potential, but much work is needed before its optimal role in the clinical environment is known.
منابع مشابه
Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملSample manuscript showing specifications and style
Barten’s model of spatio-temporal contrast sensitivity function of human visual system is embedded in a multi-slice channelized Hotelling observer. This is done by 3D filtering of the stack of images with the spatio-temporal contrast sensitivity function and feeding the result (i.e., the perceived image stack) to the multi-slice channelized Hotelling observer. The proposed procedure of consider...
متن کاملTitle: Simulation of 3D DLA masses in digital breast tomosynthesis
Digital breast tomosynthesis (DBT) is suggested to have superior performance compared to 2D mammography in terms of cancer visibility, especially in the case of dense breasts. However, the overall performance of tomosynthesis for screening applications, and the manner in which tomosynthesis should be optimally used for screening remains unclear. This motivates the development of software tools ...
متن کاملThe simulation of 3D microcalcification clusters in 2D digital mammography and breast tomosynthesis.
PURPOSE This work proposes a new method of building 3D models of microcalcification clusters and describes the validation of their realistic appearance when simulated into 2D digital mammograms and into breast tomosynthesis images. METHODS A micro-CT unit was used to scan 23 breast biopsy specimens of microcalcification clusters with malignant and benign characteristics and their 3D reconstru...
متن کاملDetection of microcalcification clusters by 2D-mammography and narrow and wide angle digital breast tomosynthesis
The aim of this study was to compare the detection of microcalcification clusters by human observers in breast images using 2D-mammography and narrow (15°/15 projections) and wide (50°/25 projections) angle digital breast tomosynthesis (DBT). Simulated microcalcification clusters with a range of microcalcification diameters (125 μm-275 μm) were inserted into 6 cm thick simulated compressed brea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJR. American journal of roentgenology
دوره 190 4 شماره
صفحات -
تاریخ انتشار 2008