Maximum Likelihood Estimators in Magnetic Resonance Imaging

نویسندگان

  • M. Dylan Tisdall
  • M. Stella Atkins
  • Richard A. Lockhart
چکیده

Images of the MRI signal intensity are normally constructed by taking the magnitude of the complex-valued data. This results in a biased estimate of the true signal intensity. We consider this as a problem of parameter estimation with a nuisance parameter. Using several standard techniques for this type of problem, we derive a variety of estimators for the MRI signal, some previously published and some novel. Using Monte Carlo experiments we compare the estimators we derive with others previously published. Our results suggest that one of the novel estimators we derive may strike a desirable trade-off between bias and mean squared error.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

I-59: Diagnostic Accuracy of Physical Examination,Transvaginal Sonography, RectalEndoscopic Sonography, and Magnetic ResonanceImaging to Diagnose Deep InfiltratingEndometriosis

Background: To compare the value of physical examination, transvaginal sonography (TVS), rectal endoscopic sonography (RES), and magnetic resonance imaging (MRI) for the assessment of different locations of deep infiltrating endometriosis (DIE). Materials and Methods: Ninety-two consecutive patients with clinical evidence of pelvic endometriosis. Physical examination, TVS, RES, and MRI, perform...

متن کامل

Use of Magnetic Resonance Imaging in Food Quality Control: A Review

Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...

متن کامل

On the Maximum Likelihood Estimators for some Generalized Pareto-like Frequency Distribution

Abstract. In this paper we consider some four-parametric, so-called Generalized Pareto-like Frequency Distribution, which have been constructed using stochastic Birth-Death Process in order to model phenomena arising in Bioinformatics (Astola and Danielian, 2007). As examples, two ”real data” sets on the number of proteins and number of residues for analyzing such distribution are given. The co...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Information processing in medical imaging : proceedings of the ... conference

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2007