Dosimetric Measurements in Isolated Human Coronary Arteries Comparison of Commercially Available Iridium With Strontium/Yttrium Emitters
نویسندگان
چکیده
Background—Intravascular brachytherapy is being applied more and more in patients with coronary artery disease for the prevention of restenosis subsequent to balloon angioplasty, in particular after stent implantation. Several radiation sources ( and -emitters) are available in clinical routine. It was the purpose of this study to compare the radiation doses at the level of the adventitia in diseased and stented human coronary arteries for Ir and Sr/Y emitters in routine use. In contrast to previously published work, we performed dosimetry instead of calculating depth-dose distribution by use of the Monte Carlo system. Methods and Results—Postmortem calcified human coronary artery segments were stented and placed in an organ bath. Commercially available -emitters (Ir; Cordis Checkmate) and -emitters (Sr/Y; Novoste Beta-Cath) were used. Relative dose distributions along the adventitia were measured by a specially designed scintillation detector system. Whereas dose perturbations caused by stents and calcified plaque were negligible for the Ir source, radiation from the beta source was significantly impaired (as much as 40%) at the level of the adventitia (3.0-mm vessel diameter). Dose perturbation was clearly dependent on the extent and severity of calcification, less affected by stent material. Conclusions—Dose perturbation caused by calcified plaque and metallic stents is significant for -sources. This dosimetric difference between and -emitters in diseased coronary arteries should be considered when calculating doses in intravascular brachytherapy. (Circulation. 2002;105:2493-2496.)
منابع مشابه
Dosimetric measurements in isolated human coronary arteries: comparison of commercially available iridium(192) with strontium/yttrium(90) emitters.
BACKGROUND Intravascular brachytherapy is being applied more and more in patients with coronary artery disease for the prevention of restenosis subsequent to balloon angioplasty, in particular after stent implantation. Several radiation sources (beta- and gamma-emitters) are available in clinical routine. It was the purpose of this study to compare the radiation doses at the level of the advent...
متن کاملDetermination of the Efficiency of Commercially Available Dose Calibrators for -Emitters
Objectives: The goals of this investigation are to determine whether commercially available dose calibrators can be used to measure the activity of -emitting radionuclides used in pain palliation and to establish whether manufacturer-supplied calibration factors are appropriate for this purpose. Methods: Six types of commercially available dose calibrators were studied. Dose calibrator response...
متن کاملComparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations
Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...
متن کاملThe comparison of absorbed dose measurements for water and artificial body fluid
Background: Advances in radiation dosimetry concepts and the development of primary measurement standards based on absorbed dose to water over the last decades offer the possibility to calibrate ionisation chambers directly in terms of absorbed dose to water. The aim of this study is the investigation on utility of artificial body fluid (ABF) instead of water by comparing dosimetric me...
متن کاملDosimetric analysis for the selection of radionuclides in bone pain palliation targeted therapy: A Monte Carlo simulation
Introduction:The use of beta emitters is one of the effective methods for palliation of bone metastasis. The risk of normal tissue toxicity should be evaluated in the bone pain palliation treatment. Methods: In this study, the Monte Carlo simulation code MCNPX was used for simulation a bone phantom model consisted of bone marrow, bone and soft tissue. Spe...