Increases in whole blood glucose measurements using optically based self-monitoring of blood glucose analyzers due to extreme Canadian winters.

نویسندگان

  • George C Cembrowski
  • Barbara Smith
  • Ellen M O'Malley
چکیده

BACKGROUND Temperature and humidity have been reported to influence the results of whole blood glucose (WBG) measurements. METHODS To determine whether patient WBG values were affected by seasonal variation, we conducted a retrospective analysis of 3 years' worth of weekly averages of patient WBG in five Edmonton hospitals. RESULTS In all five hospitals, the winter WBG averages were consistently higher than the summer WBG averages, with the differences varying between 5% and 9%. Whole blood glucose averages were negatively correlated with the outside temperature. This seasonal variation was not observed in weekly patient averages of specimens run in a central hospital laboratory. INTERPRETATION It is probable that the seasonal variation of WBG arises from the very low indoor humidities that are associated with external subzero temperatures. These increases in WBG in cold weather may be due to limitations in the WBG measuring systems when operated in decreased humidities and/or increased evaporation of the blood sample during the blood glucose measurement process. The implications of this seasonal variation are significant in that it (1) introduces increased variability in patient WBG, (2) may result in increased glucose-lowering therapy during periods of external cold and low indoor humidity, and (3) confounds evaluations of WBG meter technology in geographic regions of subzero temperature and low indoor humidity. To mitigate the risk of diagnosing and treating factitious hyperglycemia, the humidity of patient care areas must be strictly controlled.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?

Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors.Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed ...

متن کامل

مقایسه میزان همخوانی یافته‌های سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد

Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...

متن کامل

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review

INTRODUCTION Glucose control to prevent both hyperglycemia and hypoglycemia is important in an intensive care unit. Arterial blood gas analyzers and glucose meters are commonly used to measure blood-glucose concentration in an intensive care unit; however, their accuracies are still unclear. METHODS We performed a systematic literature search (January 1, 2001, to August 31, 2012) to find clin...

متن کامل

تأثیر مداخله آموزشی مبتنی بر الگوی مراقبت پیگیر بر خودپایشی قند خون بیماران دیابتی نوع 2

Background and Aim: Appropriate control of blood sugar delays the onset and progression of diabetes mellitus (DM) complications. Nurses have a decisive role in the education of self-care behaviors to diabetic patients, including self-monitoring of blood glucose. The current study aimed at assessing the effect of educational intervention based on continuous care model on self-monitoring of blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 2009