Applicability of a risk score for prediction of the long-term (8-year) benefit of the implantable cardioverter-defibrillator.

نویسندگان

  • Alon Barsheshet
  • Arthur J Moss
  • David T Huang
  • Scott McNitt
  • Wojciech Zareba
  • Ilan Goldenberg
چکیده

OBJECTIVES The present study was designed to explore the 8-year survival benefit of a nonresynchronization implantable cardioverter-defibrillator (ICD) according to a simple risk stratification score. BACKGROUND There is limited information regarding factors that predict the benefit of primary prevention with an ICD during long-term follow-up. METHODS This study used a previously developed risk score including 5 clinical factors (New York Heart Association functional class >II, age >70 years, blood urea nitrogen >26 mg/dl, QRS duration >0.12 s, and atrial fibrillation) to evaluate 8-year ICD survival benefit within risk score categories among 1,191 MADIT-II (Multicenter Automatic Defibrillator Implantation Trial II) patients. RESULTS Patients with low (0 risk factors, n = 345) and intermediate risk (1 to 2 risk factors, n = 646) demonstrated a significantly higher probability of survival at 8-year follow-up when treated by ICD as compared with non-ICD therapy (75% vs. 58%, p = 0.004; and 47% vs. 31%, p < 0.001, respectively). By contrast, among high-risk patients (3 or more risk factors, n = 200), there was no significant difference in 8-year survival between the ICD and non-ICD subgroups (19% vs. 17%, p = 0.50). Consistently, multivariate analysis showed that ICD therapy was associated with a significant long-term survival benefit among low- and intermediate-risk patients (hazard ratio [HR]: 0.52, p < 0.001, and HR: 0.66, p < 0.001, respectively), whereas treatment with an ICD was not associated with a significant benefit among high-risk patients (HR: 0.84, p = 0.25). CONCLUSIONS These findings suggest that a simple risk score can identify patients who derive significant long-term benefit from primary ICD therapy. High-risk patients with multiple comorbidities composed 17% of the MADIT-II population and did not derive long-term benefit from nonresynchronization device therapy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

Long-term benefit of primary prevention with an implantable cardioverter-defibrillator: an extended 8-year follow-up study of the Multicenter Automatic Defibrillator Implantation Trial II.

BACKGROUND The Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II) showed a significant 31 reduction in the risk of death with primary implantable cardioverter-defibrillator (ICD) therapy during a median follow-up of 1.5 years. However, currently there are no data on the long-term efficacy of primary defibrillator therapy. METHODS AND RESULTS MADIT-II enrolled 1232 patients w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 59 23  شماره 

صفحات  -

تاریخ انتشار 2012