Synthetic ECG-gated cardiac computed tomography for in vivo imaging of the temporary total artificial heart.

نویسندگان

  • Michael A Winkler
  • Paul F von Herrmann
  • Michael A Brooks
  • Charles W Hoopes
  • Anil Attili
  • Vincent L Sorrell
چکیده

To date, there have been >1000 implantations of temporary total artificial hearts (TAH-t). As expected, complications related to the use of the TAH-t can occur. A noninvasive imaging modality that would be capable of diagnosing mechanical failure, surgical complications, and thromboembolic phenomena related to the TAH-t is desirable. Echocardiography is not suitable to evaluate a TAH-t because ultrasound cannot penetrate air and the polyurethane components in the TAH-t assembly. Cardiac magnetic resonance imaging is likewise unsuitable because of the susceptibility to artifacts that the titanium valve components in the TAH-t would create. Conventional computed tomography (CT) is limited by motion artifact. Cardiac CT (CCT) can produce motion-artifact–free images of the heart. If performed with retrospective gating, CCT can also be used to acquire time-resolved images. However, CCT requires simultaneous recording of the patient’s ECG, and patients who have a TAH-t do not generate an ECG. Consequently, a variation in technique is necessary to image patients with TAH-t with this modality. Detailed below is a simple method of CCT for the TAH-t that uses a patient simulator device to generate a synthetic ECG signal. A patient simulator device is a readily available instrument normally used to test and calibrate ECG machines. A 20-year-old male patient presented with severe pain in his left torso 74 days after implantation of a TAH-t (SynCardia TAH-t, SynCardia Systems Inc, Tucson, AZ). At the time of presentation, the patient weighed 90 kg and had a body surface area of 2.13 m. His creatinine and glomerular filtration rate were normal (0.87 mg/dL and >60 mL/min, respectively). The patient’s surgeon requested a CCT of the thorax followed by a helical CT scan of the abdomen to help determine the cause of the pain. A dual-source, 32–detector-row, Z-flying focal spot CT scanner (SOMATOM Definition, Siemens Healthcare, Forchheim, Germany) was used to perform the scan. The

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac Function Electrocardiogram-Gated Single-Photon Emission Computed Tomography Versus Cardiac Magnetic Resonance Imaging for the Assessment of Left Ventricular Volumes and Ejection Fraction A Meta-Analysis

OBJECTIVES The purpose of this study was to evaluate the accuracy of electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT) for assessment of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) compared with the gold standard of cardiac magnetic resonance imaging (MRI). BACKGROUND Several comparisons of ECG-gated SPECT...

متن کامل

Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: a meta-analysis.

OBJECTIVES The purpose of this study was to evaluate the accuracy of electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT) for assessment of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) compared with the gold standard of cardiac magnetic resonance imaging (MRI). BACKGROUND Several comparisons of ECG-gated SPE...

متن کامل

Evaluating adult cor triatriatum with total anomalous pulmonary venous connections by multidetector computed tomography angiography.

A 19-year-old female patient was admitted to our hospital with dyspnea, chest pain, and shortness of breath. A chest radiograph showed mild cardiomegaly. Echocardiography revealed an extra chamber in the heart. To evaluate this abnormality, ECG-gated 16-detector-row computed tomography angiography was performed. Multidetector computed tomography (MDCT), showing cor triatriatum with total anomal...

متن کامل

Influence of trigger type, tube voltage and heart rate on calcified plaque imaging in dual source cardiac computed tomography: phantom study

BACKGROUND To investigate the impact of high pitch cardiac CT vs. retrospective ECG gated CT on the quantification of calcified vessel stenoses, with assessment of the influence of tube voltage, reconstruction kernel and heart rate. METHODS A 4D cardiac movement phantom equipped with three different plaque phantoms (12.5%, 25% and 50% stenosis at different calcification levels), was scanned w...

متن کامل

Comparison of non-gated vs. electrocardiogram-gated 64-detector-row computed tomography for integrated electroanatomic mapping in patients undergoing pulmonary vein isolation.

AIMS To compare non-gated vs. electrocardiogram (ECG)-gated 64-detector-row computed tomography (MDCT) of the left atrium (LA) for integrated electroanatomic mapping (EAM) in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS Twenty-nine consecutive patients with paroxysmal AF underwent MDCT prior to pulmonary vein isolation (PVI). All patients were in sinus rhythm both du...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 127 1  شماره 

صفحات  -

تاریخ انتشار 2013