Tine after tine: a varied approach to the removal of a long-standing IVC filter

نویسندگان

  • Andrew Delozier
  • Melhem Ghaleb
  • Alonso Andrade
چکیده

Inferior vena cava filters are important tools used to help prevent life-threatening pulmonary embolisms in hospitalized patients with contraindications to pharmacological prophylactic anticoagulation. This is a case report of a patient who had an inferior vena cava filter placed after a traumatic subdural hematoma. He made a complete recovery but was lost to follow-up until he presented 1825 days after filter deployment with abdominal pain discovered to be from penetration of the filter tines outside the lumen and into adjacent structures. We describe a case complicated by fibrotic tine entrapment with penetration to surrounding structures and discuss the technical approach used to free and eventually remove the long-standing filter.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی درمان6 بیمار دارای فیلتر وناکاوا دائمی جهت پیشگیری از امبولی ریوی

Introduction & Objective: Venous thromboembolic disease is a significant cause of morbidity and mortality in the United States. Deep venous thrombosis (DVT) and pulmonary embolism (PE) are a spectrum of a single disease entity. In most clinical situations, anticoagulation is the preferred form of therapy .IVC filter placement when using anticoagulation therapy is contraindicated or proves i...

متن کامل

Cardiovascular effects of nitrergic system of the pedunculopon-tine tegmental nucleus in anesthetized rats

Objective(s): Nitric oxide (NO) is an important neurotransmitter in central nervous system involved in central cardiovascular regulation. The presence of NO in the pedunculopontine tegmental (PPT) nucleus has been shown, but its cardiovascular effect has not been determined. In the present study, the cardiovascular effect of NO in the PPT nucleus was evaluated. Materials and Methods: After indu...

متن کامل

Blood coagulation in arthropods. II. Phase contrast microscopic observations on hemolymph coagulation in sixty-one species of insects.

II i-lAS BEEN SI-1O\VN elsewheu’e (Gn’ goin’e aunt! Florkins,#{176} r ) that tine type of hemolymph ot)agulatiOns ins tine house -n’icket (Gryilulus (lomesticus) anod inn tise Sti(’k inssect (Cai’ausiris inorosiis), as stuttied by pinase o’ountrast microscopy, simO)iVs tO si rikinsg ausalogy siitin tine pn’ooess of o’oagulations tlestrii)ed inn cn’usta(’eanl blood, espe(’ially ivitin type (1 of...

متن کامل

Recurrent Fracture of a Recovery Inferior Vena Cava Filter with Pulmonary Migration

Inferior vena cava (IVC) filters are indicated in patients with venous thromboembolic disease in whom standard anticoagulation therapy is contraindicated or ineffective. A 32-year-old female presented to our hospital with chest pain 5 years after IVC filter placement. Imaging revealed sequential fracturing and embolization of two of the IVC filter arms to the pulmonary arteries. IVC filter frac...

متن کامل

Ligand interaction with hemoprotein P-450. 3. The use of n-octylamine and ethyl isocyanide difference spectroscopy in the quantitative determination of high- and low-spin P-450.

A simple metinod for tine determinations, by ligannd binndinug to octylaminie, of tine absolute amounts of inigharid loss--spins formsss of huemoproteini P-450 of rabbit liver microsomcs is described. A correlationn betus-eenn octvlrsminse bimsdinsg to tine two forms of oxidized P-450 and the binsdinsg of ethyl isocyanide to reduced P-450 inas beeni observed, and advantages of tine aminc-binidi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017