Future Bearing Surfaces in Total Hip Arthroplasty

نویسنده

  • Jun-Dong Chang
چکیده

One of the most important issues in the modern total hip arthroplasty (THA) is the bearing surface. Extensive research on bearing surfaces is being conducted to seek an ideal bearing surface for THA. The ideal bearing surface for THA should have superior wear characteristics and should be durable, bio-inert, cost-effective, and easy to implant. However, bearing surfaces that are currently being implemented do not completely fulfill these requirements, especially for young individuals for whom implant longevity is paramount. Even though various new bearing surfaces have been investigated, research is still ongoing, and only short-term results have been reported from clinical trials. Future bearing surfaces can be developed in the following ways: (1) change in design, (2) further improvement of polyethylene, (3) surface modification of the metal, (4) improvement in the ceramic, and (5) use of alternative, new materials. One way to reduce wear and impingement in THA is to make changes in its design by using a large femoral head, a monobloc metal shell with preassembled ceramic liner, dual mobility cups, a combination of different bearing surfaces, etc. Polyethylene has improved over time with the development of highly crosslinked polyethylene. Further improvements can be made by reinforcing it with vitamin E or multiwalled carbon nanotubes and by performing a surface modification with a biomembrane. Surface modifications with titanium nitride or titanium niobium nitride are implemented to try to improve the metal bearings. The advance to the fourth generation ceramics has shown relatively promising results, even in young patients. Nevertheless, further improvement is required to reduce fragility and squeaking. Alternative materials like diamond coatings on surfaces, carbon based composite materials, oxidized zirconium, silicon nitride, and sapphire are being sought. However, long-term studies are necessary to confirm the efficacy of these surfaces after enhancements have been made with regard to fixation technique and implant quality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

A critical appraisal of the evidence regarding the choice of common bearing couples available for total hip arthroplasty.

There are a variety of materials used in bearing components in total hip replacement (THR). Metal-on-polyethylene replacements, having undergone small technical refinements in design over the last 30- 40 years, give, according to the Scandinavian hip register, very good 10-year outcomes. However, aseptic loosening, caused to a great extent by adverse biological local reactions, induced by wear ...

متن کامل

The Epidemiology and National Trends of Bearing Surface Usage in Primary Total Hip Arthroplasty in Korea

BACKGROUND We analyzed the data for primary total hip arthroplasty (THA) in the Korean nationwide database to assess (1) the epidemiology and national trends of bearing surface usage in THAs and (2) the prevalence of each type of bearing surface according to age, gender, hospital type, primary payer, and hospital procedure volume. METHODS A total of 30,881 THAs were analyzed using the Korean ...

متن کامل

Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty

The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinic...

متن کامل

The Bearing Surfaces in Total Hip Arthroplasty – Options, Material Characteristics and Selection

During total hip arthroplasty, both the femoral and acetabular bearing surfaces are surgically replaced with metallic, polymeric, and/or ceramic components. Throughout the twentieth century, many different combinations of these materials have been proposed and examined as bearing surfaces for total hip arthroplasty. Metal-on-metal total hip replacements were first implanted by Wiles in the 1930...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014