Test-retest reliability and reproducibility of short-echo-time spectroscopic imaging of human brain at 3T.

نویسندگان

  • Charles Gasparovic
  • Edward J Bedrick
  • Andrew R Mayer
  • Ronald A Yeo
  • Hongji Chen
  • Eswar Damaraju
  • Vince D Calhoun
  • Rex E Jung
چکیده

A 1H magnetic resonance spectroscopic imaging study at 3T and short echo time was conducted to evaluate both the reproducibility, as measured by the interscan coefficient of variation (CV), and test-retest reliability, as measured by the intraclass correlation coefficient (ICC), of measurements of glutamate (Glu), combined glutamate and glutamine (Glx), myo-inositol (mI), N-acetylaspartate, creatine, and choline in 21 healthy subjects. The effect of partial volume correction on these measures and the relationship of reproducibility and reliability to data quality were also examined. A 1H magnetic resonance spectroscopic imaging slice was prescribed above the lateral ventricles and single repeat scans were performed within 30 min to minimize physiologic variability. Interscan CVs based on all the voxels varied from 0.05 to 0.07 for N-acetylaspartate, creatine, and choline to 0.10-0.13 for mI, Glu, and Glx. Findings on the reproducibility of gray and white matter estimates of N-acetylaspartate, creatine, and choline are consistent with previous studies using longer echo times, with CVs in the range of 0.02-0.04 and ICC in the range of 0.65-0.90. CVs for Glu, Glx, and mI are much lower than reported in previous studies at 1.5 T, while white matter mI (CV=0.04, ICC=0.93) and gray matter Glx (CV=0.04, ICC=0.68) demonstrated both high reproducibility and test-retest reliability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of Glutamate Quantification in Human Nucleus Accumbens Using Proton Magnetic Resonance Spectroscopy at a 70-cm Wide-Bore Clinical 3T MRI System

The human nucleus accumbens is a challenging region to study using proton magnetic resonance spectroscopy (1H-MRS) on a 70-cm wide-bore clinical 3T MRI system. The aim of this study was to investigate the reliability for quantitative measurement of glutamate concentration in the nucleus accumbens using a 70-cm wide-bore clinical 3T MRI. 1H-MRS of the nucleus accumbens was acquired using the Poi...

متن کامل

Accelerated echo-planar J-resolved spectroscopic imaging in the human brain using compressed sensing: a pilot validation in obstructive sleep apnea.

BACKGROUND AND PURPOSE Echo-planar J-resolved spectroscopic imaging is a fast spectroscopic technique to record the biochemical information in multiple regions of the brain, but for clinical applications, time is still a constraint. Investigations of neural injury in obstructive sleep apnea have revealed structural changes in the brain, but determining the neurochemical changes requires more de...

متن کامل

Brain morphometry reproducibility in multi-center 3 T MRI studies: A comparison of cross-sectional and longitudinal segmentations

Large-scale longitudinal multi-site MRI brain morphometry studies are becoming increasingly crucial to characterize both normal and clinical population groups using fully automated segmentation tools. The test-retest reproducibility of morphometry data acquired across multiple scanning sessions, and for different MR vendors, is an important reliability indicator since it defines the sensitivity...

متن کامل

Feasibility and Reproducibility of Echo Planar Spectroscopic Imaging on the Quantification of Hepatic Fat

OBJECTIVES 1H-MRS is widely regarded as the most accurate noninvasive method to quantify hepatic fat content (HFC). When practical period of breath holding, and acquisition of HFC over multiple liver areas is considered, a fast MR spectroscopic imaging technique is desired. The aim of this study is to examine the feasibility and reproducibility of echo planar spectroscopic imaging (EPSI) on the...

متن کامل

Reproducibility and variance of serial short echo time 1H magnetic resonance spectroscopic imaging of the human brain at 3T with automated planning software

S. Van Cauter, D. Sima, L. ter Beek, J. Luts, Y. Li, M. I. Osorio Garcia, S. Sunaert, S. Van Huffel, and U. Himmelreich Department of Radiology, University Hospitals Leuven, Leuven, Belgium, Department Electrical Engineering – ESAT/SCD, Catholic University Leuven, Philips Medical Systems, School of Electronical Engineering, University of Electronic science and technology of China, Chengdu, Chin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 66 2  شماره 

صفحات  -

تاریخ انتشار 2011