100% Efficient three-dimensional coronary MR angiography with two-dimensional beat-to-beat translational and bin-to-bin affine motion correction.

نویسندگان

  • Andrew P Aitken
  • Markus Henningsson
  • Rene M Botnar
  • Tobias Schaeffter
  • Claudia Prieto
چکیده

PURPOSE To develop a flexible image navigator for 3D coronary MR angiography that allows respiratory motion of variable complexity to be compensated for on different temporal scales. METHODS A two-dimensional (2D) golden radial image navigator is proposed; translational motion is compensated for on a beat-to-beat basis, and residual affine motion is compensated for on a bin-to-bin basis in a two-step procedure. The method does not use a respiratory gating window and therefore achieves 100% scan efficiency and a predictable scan time. The proposed method was tested in 11 healthy volunteers and compared against a navigator-gated and tracked acquisition. RESULTS The proposed method achieved comparable quantitative and qualitative image quality to a 6-mm navigator-gated and tracked scan while reducing the scan time by a factor of approximately 2. Combined motion correction using image navigators improved visualization of the coronary arteries in four of 11 subjects in comparison with translational correction only, and image quality was maintained in the remaining cases. In one case, visualization of the left anterior descending coronary artery was degraded using combined correction compared with translation correction only. CONCLUSIONS The feasibility of correcting for 2D translational motion on a beat-to-beat basis as well as affine motion on a bin-to-bin basis has been demonstrated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D Coronary MRA with 2D beat-to-beat translational and bin-to-bin affine respiratory motion correction using a golden radial image navigator

Figure 2 – Reformatted images showing the main coronary arteries of two subjects. Subject 1: 2D Affine + translational motion correction gives superior image quality compared to both 2D translational correction and a gated scan (with ~3x reduction in scan time). Subject 2: 2D motion correction gives similar image quality to the gated scan with ~2x reduction in scan time. Affine correction shows...

متن کامل

Technical note: Accelerated nonrigid motion‐compensated isotropic 3D coronary MR angiography

PURPOSE To develop an accelerated and nonrigid motion-compensated technique for efficient isotropic 3D whole-heart coronary magnetic resonance angiography (CMRA) with Cartesian acquisition. METHODS Highly efficient whole-heart 3D CMRA was achieved by combining image reconstruction from undersampled data using compressed sensing (CS) with a nonrigid motion compensation framework. Undersampled ...

متن کامل

Highly efficient nonrigid motion‐corrected 3D whole‐heart coronary vessel wall imaging

PURPOSE To develop a respiratory motion correction framework to accelerate free-breathing three-dimensional (3D) whole-heart coronary lumen and coronary vessel wall MRI. METHODS We developed a 3D flow-independent approach for vessel wall imaging based on the subtraction of data with and without T2-preparation prepulses acquired interleaved with image navigators. The proposed method corrects b...

متن کامل

Motion Corrected 3D Whole-Heart Vessel Wall Imaging

Background Coronary atherosclerosis is not necessarily stenotic, due to outward remodeling of the vessel wall. Plaque burden correlates with risk of coronary disease (Kubo et al, J Am Coll Cardiol 2007) and direct visualization is desired. A 3D flow independent approach for vessel wall imaging was proposed recently (Andia et al, MRM 2013), based on subtraction of data with (T2prep(+)) and witho...

متن کامل

Extending Two-Dimensional Bin Packing Problem: Consideration of Priority for Items

In this paper a two-dimensional non-oriented guillotine bin packing problem is studied when items have different priorities. Our objective is to maximize the total profit which is total revenues minus costs of used bins and wasted area. A genetic algorithm is developed to solve this problem where a new coding scheme is introduced. To evaluate the performance of the proposed GA, first an upper b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 74 3  شماره 

صفحات  -

تاریخ انتشار 2015