Comparison of different types of commercial filtered backprojection and ordered-subset expectation maximization SPECT reconstruction software.

نویسندگان

  • Alain Seret
  • Julien Forthomme
چکیده

UNLABELLED The aim of this study was to compare the performance of filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM) reconstruction algorithms available in several types of commercial SPECT software. METHODS Numeric simulations of SPECT acquisitions of 2 phantoms were used: the National Electrical Manufacturers Association line phantom used for the assessment of SPECT resolution and a phantom with uniform, hot-rod, and cold-rod compartments. For FBP, no filtering and filtering of the projections with either a Butterworth filter (order 3 or 6) or a Hanning filter at various cutoff frequencies were considered. For OSEM, the number of subsets was 1, 4, 8, or 16, and the number of iterations was chosen to obtain a product number of iterations times the number of subsets equal to 16, 32, 48, or 64. The line phantom enabled us to obtain the reconstructed central, radial, and tangential full width at half maximum. The uniform compartment of the second phantom delivered the reconstructed mean pixel counts and SDs from which the coefficients of variation were calculated. Hot contrast and cold contrast were obtained from its rod compartments. RESULTS For FBP, the full width at half maximum, mean pixel count, coefficient of variation, and contrast were almost software independent. The only exceptions were a smaller (by 0.5 mm) full width at half maximum for one of the software types, higher mean pixel counts for 2 of the software types, and better contrast for 2 of the software types under some filtering conditions. For OSEM, the full width at half maximum differed by 0.1-2.5 mm with the different types of software but was almost independent of the number of subsets or iterations. There was a marked dependence of the mean pixel count on the type of software used, and there was a moderate dependence of the coefficient of variation. Contrast was almost software independent. The mean pixel count varied greatly with the number of iterations for 2 of the software types, and the coefficient of variation increased with the number of iterations for all types of software. The mean pixel count, coefficient of variation, and contrast were almost constant for a fixed product number of iterations times the number of subsets, whatever the number of subsets or iterations. CONCLUSION Most of the types of software were equivalent for FBP or OSEM reconstruction. However, a few differences were observed with some types of software and should be considered when they are used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of a noise-weighted filtered backprojection algorithm with the Standard MLEM algorithm for poisson noise.

Iterative maximum-likelihood expectation maximization and ordered-subset expectation maximization algorithms are excellent for image reconstruction and usually provide better images than filtered backprojection (FBP). Recently, an FBP algorithm able to incorporate noise weighting during reconstruction was developed. This paper compares the performance of the noise-weighted FBP algorithm and the...

متن کامل

Impact of reconstruction method on quantitative parameters of 99mTc-TRODAT-1 SPECT

Introduction: Quantitative evaluation is recommended to improve diagnostic ability and serial assessment of dopamine transporter (DAT) density scans. We decided to compare the ordered subsets expectation-maximization (OSEM) with filtered back-projection (FBP), and to investigate the impact of different iteration and cut-off frequencies on SBR values. Methods</stro...

متن کامل

Characterization of ordered-subsets expectation maximization with 3D post-reconstruction Gauss filtering and comparison with filtered backprojection in 99mTc SPECT.

PURPOSE To characterize ordered-subset expectation maximization algorithm with a fixed 3D Gauss post-reconstruction filtering (OSEM) in 99mTc SPECT as for noise, contrast and spatial resolution with varying number of subset and iteration and to compare OSEM with an optimized set of parameters, with filtered backprojection (FBP) with filter parameters typical of brain and myocardial SPECT, both ...

متن کامل

A non-parametric bootstrap approach for analysing the statistical properties of SPECT and PET images.

Knowledge of the statistical properties of reconstructed single photon emission computed tomography (SPECT) and positron emission tomography (PET) images would be helpful for optimizing acquisition and image processing protocols. We describe a non-parametric bootstrap approach to accurately estimate the statistical properties of SPECT or PET images whatever the noise properties in the projectio...

متن کامل

Single Photon Imaging and Instrumentation

Abbreviations 2D, 3D 2-dimensional, 3-dimensional CZT cadmium zinc telluride EKG electric signal from the heart FBP filtered backprojection FOV field-of-view GE General Electric Ge(Li) germanium detector doped with lithium MLEM maximum likelihood expectation maximization NaI(Tl) sodium iodine doped with thallium NM nuclear medicine OSEM ordered subset expectation maximization PET positron emiss...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2009