Automatic off-resonance correction with piecewise linear autofocus

نویسندگان

  • Travis Smith
  • Krishna Nayak
چکیده

(red arrows) and other places, the proposed method removes more offresonance artifacts than conventional autofocus and produces images comparable to field map-based correction. The estimated field map also exhibits better agreement with measurement except in featureless areas (white circle). Eq 1: fo(x,y) = fc + fxx + fyy Eq 2: so(kx,ky) = e–j2πfct s(kx+fxt,ky+fyt) Eq 3: s(0,0) = e+j2πfcTE so(–fxTE, –fyTE)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast automatic linear off-resonance correction method for spiral imaging.

Field inhomogeneity and susceptibility variations, coupled with a long readout, can result in image blurring in spiral imaging. Many correction methods based on a priori off-resonance information, such as an acquired field map, have been proposed in the literature. Automatic off-resonance correction methods are alternative approaches that estimate a field map from the image data themselves. In ...

متن کامل

Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectory.

PURPOSE To implement a nonrigid autofocus motion correction technique to improve respiratory motion correction of free-breathing whole-heart coronary magnetic resonance angiography acquisitions using an image-navigated 3D cones sequence. METHODS 2D image navigators acquired every heartbeat are used to measure superior-inferior, anterior-posterior, and right-left translation of the heart durin...

متن کامل

Autofocus algorithm for dispersion correction in optical coherence tomography.

Practical clinical optical coherence tomography (OCT) systems require automatic tools for identifying and correcting flaws in OCT images. One type of flaw is the loss of image detail owing to the dispersion of the medium, which in most cases is unknown. We present an autofocus algorithm for estimating the delay line and material dispersion from OCT reflectance data, integrating a previously pre...

متن کامل

Interactive non-uniformity correction and intensity standardization of MR images

Image non-uniformity and intensity non-standardness are two major hurdles encountered in human and computer interpretation and analysis of magnetic resonance (MR) images. Automated methods for image non-uniformity correction (NC) and intensity standardization (IS) may fail because solutions for them require identifying regions representing the same tissue type for several different tissues, and...

متن کامل

New approach for attenuation correction in SPECT images, using linear optimization

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...