Bone Response to Two Dental Implants with Different Sandblasted/Acid-Etched Implant Surfaces: A Histological and Histomorphometrical Study in Rabbits
نویسندگان
چکیده
Background Scientific evidence in the field of implant dentistry of the past 20 years established that titanium rough surfaces have shown improved osseointegration rates. In a majority of dental implants, the surface microroughness was obtained by grit blasting and/or acid etching. The aim of the study was to evaluate in vivo two different highly hydrophilic surfaces at different experimental times. Methods Calcium-modified (CA) and SLActive surfaces were evaluated and a total of 18 implants for each type of surface were positioned into the rabbit articular femoral knee-joint in a split model experiment, and they were evaluated histologically and histomorphometrically at 15, 30, and 60 days of healing. Results Bone-implant contact (BIC) at the two-implant surfaces was significantly different in favor of the CA surface at 15 days (p = 0.027), while SLActive displayed not significantly higher values at 30 (p = 0.51) and 60 days (p = 0.061). Conclusion Both implant surfaces show an intimate interaction with newly formed bone.
منابع مشابه
Sandblasted and acid-etched dental implants: a histologic study in rats.
PURPOSE Current literature has revealed that surface etching of endosseous implants can improve bone-implant contact. The aim of this study was to evaluate the differences in bone-implant contact (BIC) between sandblasted/acid-etched and machined-surface implants. MATERIALS AND METHODS Thirty-two Sprague-Dawley rats were used in this study. Two implant surfaces, Ecotek (sandblasted/ acid-etch...
متن کاملOsseointegration of zirconia implants with different surface characteristics: an evaluation in rabbits.
PURPOSE Zirconia ceramics are a viable alternative to titanium for use as dental implants. However, the smooth surface of zirconia means that longer healing periods are needed to accomplish osseointegration compared to roughened titanium surfaces. Surface modifications can be used to increase the roughness of zirconia. The aim of this study was to assess histologically and compare the degree of...
متن کاملHistomorphometric evaluation of six dental implant surfaces after early loading in augmented human sinuses.
This study investigated the bone-to-implant contact (BIC) and osteoconductive capacity (OC) of 6 different implant surfaces after early loading in humans. Two implants with different surfaces were placed side-by-side in the grafted (n= 5) and nongrafted (n = 1) sinuses of 3 volunteers. Single-tooth restorations were delivered 60 days later. After 6 months of full occlusal loading, implants were...
متن کاملBiomechanical evaluation of a titanium implant surface conditioned by a hydroxide ion solution.
Two groups of titanium dental implants, identical in geometry but different in the treatment of their surfaces, were tested in an in vivo minipig model of the mandible. The surfaces that were tested were, first, sandblasted and acid-etched; and secondly, sandblasted, acid-etched, and conditioned. The removal torque was assessed at 2, 4, and 8 weeks after implantation (n=6 animals in each healin...
متن کاملOsseointegration of chemically modified sandblasted and acid-etched titanium implant surface in diabetic rats: a histological and scanning electron microscopy study.
INTRODUCTION The aim of this study is to assess the osseointegration of different dental implants surfaces in diabetic rats. MATERIALS AND METHODS In this study, were used 56 male Wistar rats, average weight of 300-350 g. Diabetes was induced by a single intraperitoneal injection of Streptozotocin. The glucose levels and weight of rats were periodically evaluated. After the diabetes mellitus ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017