Liquid and solid-state Cl- -sensitive microelectrodes. Characteristics and application to intracellular Cl- activity in Balanus photoreceptor

نویسندگان

  • J H Saunders
  • H M Brown
چکیده

When intracellular chloride activity (aiCl) was monitored with chloride-sensitive liquid ion exchanges (CLIX) microelectrodes in Balanus photoreceptors, replacement of extracellular chloride (Cl0) by methanesulfonate or glutamate was followed by a rapid but incomplete loss of aiCl. When propionate was used as the extracellular anion substitute, CLIX electrodes detected an apparent gain in aiCl, while a newly designed Ag-AgCl wire-in glass microelectrode showed a loss of aiCl under the same conditions. This discrepancy in Cl- washout when propionate replaced Cl0 is explained by the differences in selectivity of CLIX and Ag-AgCl electrodes for native intracellular anions and for the extracellular anion substitute which also replaces Cli and interferes in the determination of aiCl. Both electrodes indicate that ECl approximately Em when the cells are bathed in normal barnacle saline, and both electrodes showed the rate of Cl washout (tau approximately 5 min) to be independent of Cli when Cl0 was replaced by glutamate. Details of Ag-AgCl microelectrode construction are presented. These electrodes were tested and found to be insensitive to the organic anion substitutes used in this study. Selectivity data of CLIX electrodes for several anions of biological interest are described.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid and Solid-State Cl--Sensitive Microelectrodes Characteristics and Application to Intracellular C1- Activity in Balanus Photoreceptor

I N T R O D U C T I O N Using chloride liquid ion exchanger (CLIX) microelectrodes similar to those described by O r m e (1969) and Walker (1971), Brown showed (1976) that chloride was passively distributed in the dark-adapted barnacle photoreceptor , i.e. he repor ted a range o f values for the internal chloride activity (a~l) and he noted that the calculated Ecl was generally within I-2 mV of...

متن کامل

Liquid and Solid-State Cl--Sensitive Microelectrodes Characteristics and Application to Intracellular C1- Activity in Balanus Photoreceptor

I N T R O D U C T I O N Using chloride liquid ion exchanger (CLIX) microelectrodes similar to those described by O r m e (1969) and Walker (1971), Brown showed (1976) that chloride was passively distributed in the dark-adapted barnacle photoreceptor , i.e. he repor ted a range o f values for the internal chloride activity (a~l) and he noted that the calculated Ecl was generally within I-2 mV of...

متن کامل

Intracellular Na+, K+, and C1- activities in Balanus photoreceptors

Ion-sensitive microelectrodes were used to measure intracellular activities (aix) of Na+, K+, and C-1 in Balanus photoreceptors. Average values of aiNa, aiK, and aiCl were 28 mM, 120 mM, and 65 mM, respectively. Equilibrium potentials calculated from these average values were: Na+ +64 mV, K+ - 77 mV, and and Cl- -42 mV; ther average value of the resting potential for all cells examined was -41 ...

متن کامل

A Sensitive Liquid Chromatographic Method for the Analysis of Clarithromycin with Pre-Column Derivatization: Application to a Bioequivalence Study

Objective(s) A sensitive liquid chromatographic method for the analysis of clarithromycin- a macrolide antibiotic- in human serum, using pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) is described. Materials and Methods The method involved liquid-liquid extraction of the drug and an internal standard (amantadine) followed by pre-column derivatization of the analytes...

متن کامل

Intracellular pH regulation in cultured embryonic chick heart cells. Na(+)-dependent Cl-/HCO3- exchange

The contribution of Cl-/HCO3- exchange to intracellular pH (pHi) regulation in cultured chick heart cells was evaluated using ion-selective microelectrodes to monitor pHi, Na+ (aiNa), and Cl- (aiCl) activity. In (HCO3- + CO2)-buffered solution steady-state pHi was 7.12. Removing (HCO3- + CO2) buffer caused a SITS (0.1 mM)-sensitive alkalinization and countergradient increase in aiCl along with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of General Physiology

دوره 70  شماره 

صفحات  -

تاریخ انتشار 1977