Survival and radiographic analysis of a glenoid component with a cementless fluted central peg.

نویسنده

  • Gordon I Groh
چکیده

BACKGROUND Aseptic loosening of glenoid components is a common problem associated with total shoulder arthroplasty and one cause for failure. A new cementless fluted glenoid component was developed and has shown excellent bony ingrowth in a canine model. HYPOTHESIS Clinical utilization of this cementless fluted pegged glenoid component in total shoulder arthroplasty would lower rates of radiolucent lines and aseptic loosening. MATERIALS AND METHODS Between January 2005 and December 2007, 83 primary shoulder arthroplasties with a minimum of 2 years' follow-up were performed with the uncemented fluted pegged glenoid component. Radiographs and records were reviewed to determine stability and survival of the glenoid component. RESULTS All cementless fluted pegged glenoid components had survived at the most recent clinical follow-up. Radiographs showed no evidence of component loosening or radiolucent lines. Evidence of fingerlike projections of bone between the flanges of the implant was found in 24 cases (29%). CONCLUSIONS A cementless fluted pegged glenoid component showed excellent initial clinical survival and integration. Further studies regarding continued durability of this component appear warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Asymmetric Reaming versus a Posteriorly Augmented Component for Posterior Glenoid Wear and Retroversion: A Radiographic Study

Background: Managing posterior glenoid wear and retroversion remains a challenge in shoulder arthroplasty.Correcting glenoid version through asymmetric reaming (AR) with placement of a standard glenoid component and theuse of posteriorly augmented glenoid (PAG) components are two methods used to address this problem. Our objectiveis to report the radiographic outcomes of patie...

متن کامل

Total shoulder arthroplasty for glenohumeral arthritis associated with posterior glenoid bone loss: results of an all-polyethylene, posteriorly augmented glenoid component.

BACKGROUND Posterior glenoid bone loss is commonly encountered in total shoulder arthroplasty (TSA). The purpose of our study is to report the clinical and radiographic findings of patients with a minimum of 2 years' follow-up treated with an all-polyethylene, augmented glenoid component. METHODS Twenty-two shoulders with posterior glenoid bone loss were treated by a single surgeon. All under...

متن کامل

Biomechanical Evaluation of All-Polyethylene Pegged Bony Ingrowth Glenoid Fixation Techniques on Implant Micromotion.

Newer glenoid components that allow for hybrid cement fixation via traditional cementation of peripheral pegs and bony ingrowth into an interference-fit central peg introduce the possibility of long-term biological fixation. However, little biomechanical work has been done on the initial stability of these components and the various fixation options. We conducted a study in which all-polyethyle...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Glenoid perforation with pegged components during total shoulder arthroplasty.

A subset of patients undergoing primary total shoulder arthroplasty (TSA) have a medialized joint line secondary to glenoid wear. In some cases, the central pegs or peripheral pegs of a peg design glenoid component may violate the medial cortex of the glenoid vault. It is unknown whether this leads to early failure. The objectives of this study were to determine (1) whether glenoid components w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 19 8  شماره 

صفحات  -

تاریخ انتشار 2010