Intravascular Optical-Resolution Photoacoustic Tomography with a 1.1 mm Diameter Catheter

نویسندگان

  • Xiaosong Bai
  • Xiaojing Gong
  • William Hau
  • Riqiang Lin
  • Jiaxiang Zheng
  • Chengbo Liu
  • Chengzhi Zeng
  • Xin Zou
  • Hairong Zheng
  • Liang Song
چکیده

Photoacoustic imaging is an emerging technology that can provide anatomic, functional, and molecular information about biological tissue. Intravascular spectroscopic and molecular photoacoustic imaging can potentially improve the identification of atherosclerotic plaque composition, the detection of inflammation, and ultimately the risk stratification of atherosclerosis. In this study, a first-of-its-kind intravascular optical-resolution photoacoustic tomography (OR-PAT) system with a 1.1 mm diameter catheter is developed, offering optical-diffraction limited transverse resolution as fine as 19.6 μm, ∼ 10-fold finer than that of conventional intravascular photoacoustic and ultrasonic imaging. To offer complementary imaging information and depth, the system also acquires co-registered intravascular ultrasound images in parallel. Imaging of an iliac stent and a lipid phantom shows that the high resolution and contrast of OR-PAT can enable improved stent implantation guidance and lipid identification. In the future, these capabilities may ultimately improve the diagnosis and interventional treatment of vulnerable atherosclerotic plaques, which are prone to cause thrombotic complications such as myocardial infarction and stroke.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-sensitivity intravascular photoacoustic imaging of lipid-laden plaque with a collinear catheter design.

A highly sensitive catheter probe is critical to catheter-based intravascular photoacoustic imaging. Here, we present a photoacoustic catheter probe design on the basis of collinear alignment of the incident optical wave and the photoacoustically generated sound wave within a miniature catheter housing for the first time. Such collinear catheter design with an outer diameter of 1.6 mm provided ...

متن کامل

Multimodal simultaneous photoacoustic tomography, optical resolution microscopy and OCT system

A novel combined photoacoustic tomography (PAT), optical resolution photoacoustic microscopy (ORPAM) and optical coherence tomography (OCT) instrument has been developed for imaging biological tissues. The system is based on the use of a Fabry-Perot (FP) polymer film ultrasound sensor. This is designed to be transparent to wavelengths between 590nm and 1200nm so that photoacoustic excitation la...

متن کامل

Prospects of photoacoustic tomography.

Commercially available high-resolution three-dimensional optical imaging modalities-including confocal microscopy, two-photon microscopy, and optical coherence tomography-have fundamentally impacted biomedicine. Unfortunately, such tools cannot penetrate biological tissue deeper than the optical transport mean free path (approximately 1 mm in the skin). Photoacoustic tomography, which combines ...

متن کامل

Patterned thin metal film for the lateral resolution measurement of photoacoustic tomography

BACKGROUND Image quality assessment method of photoacoustic tomography has not been completely standardized yet. Due to the combined nature of photonic signal generation and ultrasonic signal transmission in biological tissue, neither optical nor ultrasonic traditional methods can be used without modification. An optical resolution measurement technique was investigated for its feasibility for ...

متن کامل

Forward-viewing photoacoustic imaging probe with bundled ultra-thin hollow optical fibers

A photoacoustic imaging system composed of a flexible bundle of thin hollow-optical fibers is proposed for endoscopic diagnosis. In this system, a bundle of 127 hollow-optical fibers with an inner diameter of 100 μm was fabricated. The total diameter of the bundle was 2.1 mm, and the minimum bending radius was around 10 mm. Owing to the small numerical aperture of hollow optical fibers, a high ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014