Fast Volumetric Radiofrequency Current Density Imaging
نویسندگان
چکیده
Introduction: Radiofrequency current density imaging (RFCDI) measures currents at the Larmor frequency [1]. It is potentially useful for applications such as predicting and monitoring RF ablation treatment patterns or measuring the effectiveness of pacemaker insulators. Currents at the Larmor frequency create magnetic fields that act as an effective B1 field, exciting magnetization. By measuring these fields with Actual Flip-angle Imaging (AFI) [2], a fast B1 mapping method, volumetric current density can be measured with scan times of only a few minutes. Using the AFI sequence for current density imaging is practical in an ablation environment because the power levels are much lower than the power used for ablation. For example, pulmonary vein ablation uses power levels on the order of 50W for durations of one to two minutes [3], whereas the AFI sequence used here has similar power levels and duration, but only a 1% duty cycle. RFCDI can be used to monitor ablation without incidentally ablating tissue itself. Theory & Methods: With Ampere’s Law, current density can be calculated from the local magnetic field. When the current is at the Larmor frequency, its associated field acts as a B1 field. Previously, RF currents were imaged using an external B1 excitation in combination with the field from the current [4]. Using a B1 mapping sequence with the current acting as the only excitation allows for faster acquisition of RF field measurements. The measured magnetic fields can be used to calculate the current density component along the main B0 field of the magnet. With a volumetric data set, the full current density vector can potentially be reconstructed [5]. AFI [2] is a steady state sequence that allows for faster, higher-SNR B1 measurements than commonly used techniques such as the double-angle method. The AFI sequence uses two alternating TR lengths to allow differing amounts of T1 recovery between them. As long as the first TR is short compared to T1, the ratio of the signals from the two TRs is dependant on the B1 magnitude but independent of T1. AFI has a speed advantage over the standard double angle method, which requires long TRs to allow for full magnetization recovery, and an SNR advantage over the saturated double angle method [6], in which magnetization must recover from full saturation. Experiments were run on a 1.5T GE Signa scanner using an external Medusa console [6] to control the RF and gradient fields. The AFI sequence parameters were TR1=25ms, TR1/TR2 ratio=8, 64x64x32 matrix with 1.4x1.4x3.8mm resolution, for a scan time of one minute. A flyback-EPI readout with 8 echoes was used to accelerate the acquisition. The phantom consisted of two tubes of NaCl solution (see Figures 1 and 2). Both tubes had the same conductivity but different radii. The current flowed down one tube and back the other, creating opposing directions of current. The total current in each tube was the same, but due to their different diameters, the current densities were different. The RF excitation was created by transmitting a 1.5ms hard pulse of Larmor frequency current through the phantom, with a quadrature head coil used to receive. Two data sets were acquired, roughly halving the magnitude of the current for the second acquisition, to cover the full range of B1 magnitudes created by the current. Phase variations due to imperfect gradient shimming were measured by using the head coil to transmit and were then removed. The phase of the B1 map was used to separate Bx and By. A Sobel derivative was used to calculate the current density from the magnetic fields. Results: The B1 maps for the central plane (Figure 3) show the expected fields. There are strong xdirected fields between the tubes, where the oppositely directed currents create reinforcing fields. There are weaker fields in the periphery, where the fields are opposed and cancel each other, including a contour of zero magnetic field where the fields from the two tubes cancel completely. Figure 4 shows opposite directions of current in each tube. The current image is noisier because it is created from spatial derivatives of the B1 images. The bottom tube has a greater density of current due to its smaller cross section. There are edge effects at the tube boundaries due to the derivative operator acting on a signal void. Discussion & Conclusions: Using the AFI sequence to measure B1 fields generated by an RF current allows a full volumetric measurement of one component of the RF current density in a total scan time of two minutes. Significant work needs to be done to improve SNR. This can be accomplished by optimizing the AFI sequence, increasing the voxel size, and using a surface coil rather than the head coil. Additionally, weighting the extremes of k-space more heavily in acquisition will improve SNR, because the spatial derivatives used to calculate the current density are equivalent to linear weightings in k-space. Future experimental work will involve testing the technique in heterogeneous media and reconstructing the missing current components to achieve full-vector current density measurements. Fast, full-vector RFCDI has many potential applications such as prediction of heat deposition in RF ablation, monitoring of conductivity changes during ablation, and safety monitoring of induced and leakage current.
منابع مشابه
The modeling of induced current density in eyes from static magnetic fields produce by MR scanner
Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...
متن کاملSpatiotemporal encoding as a robust basis for fast three-dimensional in vivo MRI.
Recent studies have described some of the new opportunities that have arisen within the context of ultrafast two-dimensional imaging with the advent of spatiotemporal encoding methods. This article explores the potential of integrating these non-Fourier, single-scan, two-dimensional MRI principles, with multi-slice and phase-encoding schemes acting along a third dimension. In unison, these comb...
متن کاملSmall-tip fast recovery imaging using non-slice-selective tailored tip-up pulses and radiofrequency-spoiling.
Small-tip fast recovery (STFR) imaging is a new steady-state imaging sequence that is a potential alternative to balanced steady-state free precession. Under ideal imaging conditions, STFR may provide comparable signal-to-noise ratio and image contrast as balanced steady-state free precession, but without signal variations due to resonance offset. STFR relies on a tailored "tip-up," or "fast re...
متن کاملI-46: Radiofrequency Ablation of Uterine Fibroids
Uterine fibroids are benign solid tumors that are present in the majority of women. While often asymptomatic, fibroids can result in abnormal uterine bleeding, pelvic pressure, pain, subfertility, dyspareunia and other symptoms. Submucous and intramural fibroids are most associated with heavy menstrual bleeding; subserosal fibroids are more often innocuous unless sufficiently large so as to con...
متن کاملBayesian Vessel Extraction for Planning of Radiofrequency-Ablation
The software-assisted planning of radiofrequency-ablation of liver tumors calls for robust and fast methods to segment the tumor and surrounding vascular structures from clinical data to allow a numerical estimation, whether a complete thermal destruction of the tumor is feasible taking the cooling effect of the vessels into account. As the clinical workflow in radiofrequency-ablation does not ...