What’s up in abdominal radiology?

نویسنده

  • Wolfgang Schima
چکیده

The advent of multi-detector array CT (MDCT) has turned many things in abdominal radiology upside down. MDCT is a technique with great possibilities for several specific applications in the abdomen. For example, the results of many well-performed clinical studies on MDCT colonography for polyp detection were presented at the ECR in Vienna and at the joint meeting of the ESGAR and SGR in Orlando. MDCT colonography achieves excellent sensitivity for the detection of polyps as small as 5 mm, but is still not reliable for the visualization of smaller polyps. Thus, the debate continues about how to proceed in patients with tiny polyps found or suspected at CT colonography. The risk of malignant transformation of such tiny polyps is virtually zero and it is probably reasonable to simply follow these patients. The amount of ionizing radiation, which has been cited as a barrier to the use of MDCT as a colorectal cancer-screening tool, can be vastly reduced. A low dose technique, with noise-reduction algorithm using edgepreserving, yields comparable results, and it brings the amount of radiation delivered during a CT colonography scan into the range of a few chest X-rays. This may open the potential for the use of MDCT in screening, similar to current screening for lung cancer. For pancreatic imaging the pendulum swings toward CT. The exquisite 3D-display of tumors and their relation to the vasculature is of real benefit to pancreatic surgeons. In several centers, studies have begun to examine preoperative chemotherapy for locally inoperable pancreatic cancer. With MDCT alone, it is not possible to assess treatment response accurately, but the combination of PET/CT to assess the biological activity of tumors is a method that offers promise for every oncologic radiologist. Is there still a role for MRI in abdominal radiology? Oh, yes. MRI has matured into a widely accepted technique for liver imaging. There are several MR contrast agents for liver imaging that can optimize studies for every indication. Even the registration of secondgeneration ultrasound contrast agents in the European Union is not likely to win against MRI and MDCT. Another example is dynamic MR imaging of the small bowel, which has indeed recovered ground from CT and barium radiography for imaging of patients with small bowel obstruction. So the days of ‘old-fashioned’ enteroclysis seem to be numbered. Functional MRI is the first imaging modality ever to show intra-abdominal adhesions reliably, and small bowel MRI can delineate all tumors. So there is life after MDCT. Since the EURATOM directive 97/43 took effect, the radiology community is committed to reducing radiation exposure to the population. More than ever, we are now asked to choose the most effective and least invasive imaging technique from a whole range of imaging modalities we have at our fingertips.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Relationship between Non-Renal Diseases and Renal Parenchymal Echogenicity in Children with Acute Abdominal Pain

Background Few results have shown that renal parenchymal echogenicity increases in pediatric patients with no concurrent renal diseases. This study aimed to investigate the relation between non-renal diseases and renal cortical echogenicity in children with acute abdominal pain. Materials and Methods  This cross- sectional study was conducted among 100 children referred to Amirkola Children’s ...

متن کامل

Assessment of Carotid Intima-Media Thickness and Infra-Renal Abdominal Aorta Diameter in Women with and Without Gestational Diabetes Mellitus-A case Control Study

Objective: Gestational diabetes mellitus occurs during pregnancy is associated with increased cardiovascular risk. Carotid intima media thickness (CIMT) is a surrogate maker of subclinical atherosclerosis. The aim of this study is assessment of relationship between CIMT and infra-renal abdominal aorta diameter in women with and without Gestational Diabetes Mellitus. Materials and Methods: Th...

متن کامل

Comparative evaluation of glycerolized bovine pericardium implant with prolene mesh for closure of large abdominal wall defects in dogs

The aim of this investigation was to evaluate the use of polypropylene mesh and glycerol preserved bovine pericardium (GBP) to repaire abdominal wall defects in 24 clinically healthy mongrel dogs using inlay and underlay techniques. Twenty four healthy mongrel dogs were used in this study. The animals were divided into two main groups according to the type of the prosthetic material used. Each ...

متن کامل

Commercial polyester/cotton fabric (Damour): a novel prosthetic material for hernioplasty in ruminants

The aim of this work was to study the possibility of using a new commercial polyester/cotton fabric to repair large sized umbilical and abdominal hernias in calves and small ruminants. Twenty-four animals (16 calves, 3 buffalo calves, 4 sheep, 1 goat) with umbilical or abdominal hernia were included in this study. The diameter of hernial ring ranged from (12-25) cm. An underlay technique was us...

متن کامل

Radiographic Presentations of Intussusception in Plain Abdominal X-Ray

Intussusception is the most common cause of intestinal obstraction in children aged 3 months to 6 years. Complete understanding of its clinical and radiographic manifestations can play a major role in the early diagnosis and treatment and prevents its complications. In this study plain abdominal X-rays of 51 patients with intussusception were evaluated. Suggestive radiographic signs of the dise...

متن کامل

Efficacy of Polypropylene Mesh Coated with Bioresorbable Membrane (Sepramesh) for the Repair of Abdominal Wall Defects in Horses

Objective: The aim of this study was to compare the use of Polypropylene mesh (Prolene) and Sepramesh, a coated Polypropylene mesh with a protective layer of Seprafilm on its visceral side, for the repair of abdominal wall defects in horses. We also aimed to quantify the consequent visceral adhesion and tissue inflammatio Design: Experimental study. Animals: Ten horses. Methods: The horses w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2002