A minimum three-year clinical and radiological follow up of the utilisation of a Cementless Multihole Mega cups in conversion hip arthroplasty--a prospective analysis.
نویسندگان
چکیده
UNLABELLED The introduction of multihole mega cup has proposed innovative answers in the management of acetabular impediments that ensued from the use of bipolar hemiarthroplasty. This study bestows a prospective analysis of the outcome of conversion surgery from bipolar hemiarthroplasty to total hip replacement in patients with acetabular complications.Forty-two patients, 22 men and 20 women, with a mean age of 59 years (range 46-69 years) who experienced complex acetabular deficiencies following bipolar hemiarthroplasty, were converted to total hip replacement between January 2008 and June 2010. Pain was the main complaint in all cases. It was primarily confined to the groin region. Limping due to shortening of the affected limb was the second main complaint (30 cases). All cases had erosion of the acetabulum with varying degrees of protrusion. Cementless mutihole cups with augmentation by autogenous bone graft from the iliac crest and large metal heads' sizes were used for conversion in all cases. After a minimum follow-up of 36 months, Harris hip scores (HHS) improved from a mean of 36.8±6.8 (range 21-59) preoperatively to a mean of 85.9±5.6 (range 71 to 94) postoperatively. Thirty six (85.7%) patients experienced no groin pain postoperatively while six patients (14.3%) described limited improvement. Postoperative complications included: dislocation in two cases which were reduced and did not result in a poor outcome later on. No patients were lost to follow-up. CONCLUSIONS Short-term results at minimum three years follow-up of multihole mega cup were encouraging regarding high capability of acetabular reconstruction with less morbidity of recipient site. Significant pain and functional improvement were noticeable, however further longer term studies are consequently recommended.
منابع مشابه
Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملA comparison of polyethylene wear rates between cemented and cementless cups. A prospective, randomised trial.
We selected randomly a consecutive series of 162 patients requiring hip replacement to receive either a cementless, hemispherical, modular, titanium acetabular cup or a cemented, all-polyethylene cup. These replacements were performed by two surgeons in four general hospitals. The same surgical technique was used and a 26 mm metal-head femoral component was used in every case. After exclusions,...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملTotal Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملNo superior performance of hydroxyapatite-coated acetabular cups over porous-coated cups
BACKGROUND AND PURPOSE Hydroxyapatite (HA) coating is believed to improve bone-implant ingrowth and long-term survival of prostheses. Recent studies, however, have challenged this view. Furthermore, HA particles may produce third-body wear and initiate aseptic loosening of implants. We report the performance of HA- and porous-coated acetabular cups in a prospective randomized trial. METHODS T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 81 1 شماره
صفحات -
تاریخ انتشار 2015