Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method

نویسندگان

  • Hakimeh Sadeghian
  • Alimohammad Hajizeinali
  • Bahareh Eslami
  • Masoumeh Lotfi-Tokaldany
  • Mahmood Sheikhfathollahi
  • Mohammad Sahebjam
  • Elham Hakki
  • Arezou Zoroufian
  • Seyed Ebrahim Kassaian
  • Mohammad Alidoosti
چکیده

BACKGROUND Transcatheter closure of atrial septal defect secundum (ASD-II) has become an alternative method for surgery. We sought to compare the two-dimensional transesophageal echocardiography (TEE) method for measuring atrial septal defect with balloon occlusive diameter (BOD) in transcatheter ASD-II closure. METHODS A total of 39 patients (71.1% female, mean age: 35.31 ± 15.37 years) who underwent successful transcatheter closure of ASD-II between November 2005 and July 2008 were enrolled in this study. Transthoracic echocardiography (TTE) and TEE were performed to select suitable cases for device closure and measure the defect size before the procedure, and BOD measurement was performed during catheterization via TEE. The final size of the selected device was usually either equal to or 1 - 2 mm larger than the BOD of the defect. RESULTS The mean defect size obtained by TEE and BOD was 18.50 ± 5.08 mm and 22.86 ± 4.76 mm, respectively. The mean difference between the values of ASD size obtained by TEE and BOD was 4.36 ± 2.93 mm. In comparison with BOD, TEE underestimated the defect size in 94.9%, but TEE value being equal to BOD was observed in 5.1%. There was a good linear correlation between the two measurements: BOD = 0.773 × ASD size by TEE+8.562; r2 = 67.9.1%. A negative correlation was found between TEE sizing and the difference between BOD and TEE values (r = -0.394, p value = 0.013). CONCLUSION In this study, BOD was larger than ASD size obtained by two-dimensional TEE. However, TEE maximal defect sizing correlates with BOD and may provide credible information in device size selection for transcatheter ASD closure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect

OBJECTIVES Transcatheter closure of a secundum atrial septal defect (ASD II) has become an effective alternative for surgical treatment. In this study we evaluated the correlation between the two-dimensional transoesophageal echocardiographic (2D TEE) sizing of ASDs and the actual diameter of occluders in patients undergoing device closure. METHODS The records of 54 patients who underwent tra...

متن کامل

Balloon Occlusive Diameter of Non-Circular Atrial Septal Defects in Transcatheter Closure with Amplatzer Septal Occluder

BACKGROUND AND OBJECTIVES The aim of this study was to investigate the balloon occlusive diameter (BOD) of non-circular defects in the transcatheter closure of atrial septal defect (ASD). SUBJECTS AND METHODS A total of 67 patients who had undergone transcatheter closure of an ASD were reviewed retrospectively. A non-circular defect was defined as the ratio of the short diameter to the long d...

متن کامل

The reliability of transthoracic and transesophageal echocardiography in predicting the size of atrial septal defect.

OBJECTIVE To determine the reliability of transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) in predicting the size of an atrial septal defect (ASD). MATERIAL AND METHODS The study included 16 patients who underwent the catheter-based procedures to close an atrial septal defect between February 2008 and December 2011 at the Paediatrics Clinic, CCU Sarajevo, after ...

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

Percutaneous retrieval of an interatrial septal occluder device embolized into the aortic arch.

Percutaneous closure of secundum atrial septal defects (ASD) may be complicated by immediate embolization. We report on a 35-year-old woman who underwent percutaneous device closure for a secundum ASD. The diameter of the defect was measured as 4 mm by two-dimensional transesophageal echocardiography and a 7-mm Figulla ASD occluder device was implanted without prior balloon sizing of the defect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -