Spontaneous modular femoral head dissociation complicating total hip arthroplasty.

نویسندگان

  • Carl T Talmo
  • Kinzie G Sharp
  • Magdalena Malinowska
  • James V Bono
  • Daniel M Ward
  • Justin LaReau
چکیده

Modular femoral heads have been used successfully for many years in total hip arthroplasty. Few complications have been reported for the modular Morse taper connection between the femoral head and trunnion of the stem in metal-on-polyethylene bearings. Although there has always been some concern over the potential for fretting, corrosion, and generation of particulate debris at the modular junction, this was not considered a significant clinical problem. More recently, concern has increased because fretting and corrosive debris have resulted in rare cases of pain, adverse local tissue reaction, pseudotumor, and osteolysis. Larger femoral heads, which have gained popularity in total hip arthroplasty, are suspected to increase the potential for local and systemic complications of fretting, corrosion, and generation of metal ions because of greater torque at the modular junction. A less common complication is dissociation of the modular femoral heads. Morse taper dissociation has been reported in the literature, mainly in association with a traumatic event, such as closed reduction of a dislocation or fatigue fracture of the femoral neck of a prosthesis. This report describes 3 cases of spontaneous dissociation of the modular prosthetic femoral head from the trunnion of the same tapered titanium stem because of fretting and wear of the Morse taper in a metal-on-polyethylene bearing. Continued clinical and scientific research on Morse taper junctions is warranted to identify and prioritize implant and surgical factors that lead to this and other types of trunnion failure to minimize complications associated with Morse taper junctions as hip implants and surgical techniques continue to evolve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Late Nontraumatic Dissociation of the Femoral Head and Trunnion in a Total Hip Arthroplasty

Background. Modular total hip arthroplasties are increasingly popular because customisation allows optimal restoration of patient biomechanics. However, the introduction of component interfaces provides greater opportunities for failure. We present a case of late nontraumatic dissociation of the head-neck interface, more than 10 years after insertion. Case Description. A 58-year-old woman had a...

متن کامل

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component

The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...

متن کامل

Late Disassembly of Femoral Head and Neck of A Modular Primary Total Hip Arthroplasty

INTRODUCTION Modular total hip arthroplasty system are now widely used, as these components increase the flexibility during primary and revision total hip arthoplasty. But this modularity itself associated with some risk of intraoperative and postoperative complications. CASE REPORT We report a case of late disassembly of a primary total arthroplasty in a 42 years old patient five years after...

متن کامل

Highly Cross-linked Polyethylene Liner Dissociation from a Cement-less Modular Acetabular Shell: Two Case Reports

Liner dissociation of polyethylene from a cementless acetabular socket following total hip arthroplasty (THA) is a rare complication. Cross-linked polyethylene liner dissociation from AMS-HA shell (KYOCERA Med, Osaka, Japan) occurred in 2 out of the 4153 (0.04%) cases approximately 10 years after undergoing surgery at our institute. First case was an 80-year-old female who underwent right THA a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 37 6  شماره 

صفحات  -

تاریخ انتشار 2014