The validity of the equilateral tetrahedron as a spatial reference system.
نویسندگان
چکیده
The error involved in the use of the equilateral tetrahedron reference system for electrocardiographic or vectorcardiographic studies has been investigated by means of an electrical dipole placed in the esophagus. Vectors plotted from the potential differences between electrodes defining the reference system were found to correspond fairly closely to the actual position of the dipole, indicating that the error is small. T HE STUDY of spatial vectorcardi-ography in progress in this laboratory prompted an examination of the equi-lateral tetrahedron, which is the reference system employed. In this system the shoulders, the pubis, and a point on the back represent the apices of the figure, and the assumption of the Einthoven hypothesis that shoulders and pubis are sufficiently removed electrically from the heart to be considered equidistant must also be applied to the electrode position on the back. On a purely anatomic basis, this seems justified , since in a study of 30 normal subjects this point on the back was found to be of equal distance from the heart as the left shoulder or even more distant.' It must also be assumed, as in the Einthoven hypothesis, that the body acts as an essentially homogeneous conducting medium. It is generally agreed that these assumptions are approximations only, but are useful in frontal plane electrocardiography. If they can be applied with similar accuracy to a volu-metric reference system, three dimensional vec-torcardiography may provide new and valuable information. In the report suggesting the use of the tetra-hedron reference system, Wilson and co-workers2 presented the results of an experiment designed to test its validity. An electric field was produced in a cadaver by means of electrodes inserted in various positions in the region of the heart. The potentials at the points representing the apices of the tetrahedron were then compared with those predicted on the basis of the known dipole position. As the authors pointed out, the results were inconclusive because of the special conditions of the experiment. The effect of death on tissue resistance and the effects of accumulation of fluid in the dependent portions of the body made the data difficult to interpret. In the experiments reported herein, the potential differences between limb electrodes and limb and back electrodes produced by a "dipole" placed in the esophagus of living subjects have been determined. It is recognized that a dipole so located is not entirely comparable to the heart in relation to …
منابع مشابه
A comparative study of spatial vectorcardiograms obtained with the equilateral tetrahedron and a corrected system of electrode placement.
Spatial vectorcardiograms of a group of normal young adults, recorded with two systems of electrode placement, have been studied. Those recorded with the equilateral tetrahedron as the reference system were similar to records previously described and had QRS-loops of two configurations. Those recorded with a method of lead placement designed to reduce the errors inherent in the commonly used re...
متن کاملA Study of the Spatial Vectorcardiogram in Left Bundle Branch Block
A method of vectorcardiography, in which the projections of the spatial veetorcardiogrami in various planes of an equilateral tetrahedron reference system are recorded, has been applied to the study of left bundle branch block. Results suggest that the method employed may provide information relative to the state of the miyocar(liutim and the extent of myocardial lesions which is not evident fr...
متن کاملThe spatial vectorcardiogram in left bundle branch block.
A method of vectorcardiography, in which the projections of the spatial veetorcardiogrami in various planes of an equilateral tetrahedron reference system are recorded, has been applied to the study of left bundle branch block. Results suggest that the method employed may provide information relative to the state of the miyocar(liutim and the extent of myocardial lesions which is not evident fr...
متن کاملStandardizing Factors
Modifications in recorder standardization are required to correct inherent scalar differences among potential differences measured in a given electrocardiographic reference frame. In the frontal plane, agreement between the resultant vectors calculated from unipolar limb lead measurements and from standard lead measurements can be obtained by standardizing the galvanometer for recording the uni...
متن کاملSpatial estimation and zoning reference evapotranspiration using geostatistical methods and geographic information system (case study: Bakhtegan Basin)
Reference Evapotranspiration (ET0) is a basic parameter for determination of irrigation program. It is one of the most important factors in water resources management and considers as a requirement for every irrigation and drainage plans. Because of the spatial variations of ET0, it is necessary to use from intrapolation methods in order to estimation of this parameter in regional studie. Using...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 2 1 شماره
صفحات -
تاریخ انتشار 1950