Metal on metal hip resurfacing versus uncemented custom total hip replacement - early results

نویسندگان

  • Nemandra A Sandiford
  • Sarah K Muirhead-Allwood
  • John A Skinner
  • Jia Hua
چکیده

INTRODUCTION There is no current consensus on the most appropriate prosthesis for treating symptomatic osteoarthritis (OA) of the hip in young, active patients. Modern metal on metal hip resurfacing arthroplasty (HR) has gained popularity as it is theoretically more stable, bone conserving and easier to revise than total hip arthroplasty. Early results of metal on metal resurfacing have been encouraging. We have compared two well matched cohorts of patients with regard to function, pain relief and patient satisfaction. METHODS This prospective study compares 2 cohorts of young, active patients treated with hip resurfacing (137 patients, 141 hips) and custom uncemented (CADCAM) stems (134 patients, 141 hips). All procedures were performed by a single surgeon. Outcome measures included Oxford, WOMAC and Harris hip scores as well as an activity score. Statistical analysis was performed using the unpaired student's t-test. RESULTS One hundred and thirty four and 137 patients were included in the hip replacement and resurfacing groups respectively. The mean age of these patients was 54.6 years. The mean duration of follow up for the hip resurfacing group was 19.2 months compared to 13.4 months for the total hip replacement group.Pre operative oxford, Harris and WOMAC scores in the THA group were 41.1, 46.4 and 50.9 respectively while the post operative scores were 14.8, 95.8 and 5.0. In the HR group, pre- operative scores were 37.0, 54.1 and 45.9 respectively compared to 15.0, 96.8 and 6.1 post operatively. The degree of improvement was similar in both groups. CONCLUSION There was no significant clinical difference between the patients treated with hip resurfacing and total hip arthroplasty in the short term.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mortality rates at 10 years after metal-on-metal hip resurfacing compared with total hip replacement in England: retrospective cohort analysis of hospital episode statistics

OBJECTIVES To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England. DESIGN Retrospective cohort study. SETTING English hospital episode statistics database linked to mortality records from the Office for National Statistics. POPULATION All adults who underwent primary elective hip replacement for osteoarthritis from ...

متن کامل

A prospective randomized clinical trial comparing metal-on-metal total hip arthroplasty and metal-on-metal total hip resurfacing in patients less than 65 years old.

The purpose of this prospective randomised study is to compare the early clinical results of the metal-on-metal hip resurfacing to metal-on-metal THA. Two hundred and ten hips were randomised between August 2003 and January 2006 (191 subjects). One hundred and two hips were implanted with an uncemented titanium tapered stem, and an uncemented titanium acetabular component and 28 mm metal-on-met...

متن کامل

Clinical and radiological outcome of stemmed hip replacement after revision from metal-on-metal resurfacing.

We report the outcome of total hip replacement in 29 failed metal-on-metal resurfacing hip replacements in which the primary surgery was performed between August 1995 and February 2005. The mean length of follow-up was five years (1.7 to 11.7). Of the 29 hip resurfacings, 19 acetabular components and all the femoral components were revised (28 uncemented stems and one cemented stem). There were...

متن کامل

Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

PURPOSE To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent unc...

متن کامل

Ion Release from Metal-on-metal Hip Resurfacing Implants Does Not Differ from Standard Metal-on-metal Total Hip Replacement

STANDARD METAL-ON-METAL TOTAL HIP REPLACEMENT *Moroni A, **Savarino L, *Cadossi M, **Greco M, **Baldini N, *Giannini S * Rizzoli Orthopaedic Institute, Bologna, Italy **Laboratory for Pathophysiology of Orthopaedic Implants, Rizzoli Orthopaedic Institute, Bologna, Italy [email protected] INTRODUCTION Modern metal-on-metal (MOM) hip resurfacing has been introduced as a less invasive method of join...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2010