Unreliability of triglyceride measurement to predict turbidity induced interference.
نویسندگان
چکیده
Lipaemic specimens are a common problem in clinical chemistry. Most laboratories will measure the concentration of triglycerides and then decide whether the analytical result is valid or not. There is a poor association between the concentration of triglycerides and an objective assessment of turbidity for visually turbid specimens. Extrapolation of triglyceride concentrations derived from the use of intravenous emulsions to visually turbid specimens found in clinical practice will overestimate the turbidity induced interference in assays (non-turbid interferences are probably the same). The evaluation of turbidity induced interference needs to be standardised using objective assessments of turbidity.
منابع مشابه
Locked Nucleic Acid-enhanced Detection of 1100delc*chek2 Germ-line Mutation in Spanish Pa- Tients with Hematologic Malignancies, María Collado
analysers. Results of an interlaboratory study. Eur J Clin Chem Clin Biochem 1995;33:31–52. 3. Pearson JR, Wells R, Wells A. Serum index identifies lipemic samples causing interference with bilirubin assay on Hitachi 717. Clin Chem 1991; 37:2014–5. 4. Twomey PJ, Don-Wauchope AC, McCullough D. Unreliability of triglyceride measurement to predict turbidity induced interference. J Clin Pathol 2003...
متن کاملEffects of specimen turbidity and glycerol concentration on nine enzymatic methods for triglyceride determination.
We compared the effects of specimen turbidity and glycerol concentration on nine enzymatic methods for triglyceride measurement. We assayed 51 specimens with triglyceride concentrations of 0.85-8.21 mmol/L (75-727 mg/dL) and turbidity at 420 nm equivalent to > or = 0.1 mmol/L (8.8 mg/dL) triglyceride (measured as part of our comparison method). The data were analyzed by multiple regression, whi...
متن کاملDoes visual turbidity correlate with serum triglyceride levels in babies on total parenteral nutrition?
INTRODUCTION Intravenous lipid is commonly used as part of total parenteral nutrition (TPN) in premature babies. The gold standard of measuring lipid tolerance involves measuring serum triglyceride levels. Many hospitals in Asia do not have this facility and rely on visual turbidity to titrate the rate of lipid infusion. The aim of this study was to determine if visual turbidity correlates with...
متن کاملDirect spectrophotometry of serum hemoglobin: an Allen correction compared with a three-wavelength polychromatic analysis.
An Allen correction and a polychromatic analysis are about equally effective in minimizing effects of interference by bilirubin and triglyceride turbidity in the direct spectrophotometry of serum hemoglobin: interference from bilirubin is nearly eliminated, that from turbidity substantially decreased. The limit of detectability of hemoglobin is 8 mg/L in the presence of a moderate concentration...
متن کاملPrevention of interference by dextran with biuret-type assay of serum proteins.
In assay of serum proteins by use of the biuret reaction, dextran can cause turbidity by formation of an insoluble complex of dextran with copper and tartrate (or EDTA) in strongly alkaline solution. Whether or not the turbidity occurs depends on the tartrate concentration: turbidity is maximal at about 10 g/L, absent at 20 g/L or more, and only slight and delayed at 4 g/L. Two biuret reagents,...